Appendix A Server specifications ························································ 1
Server models and chassis view ··································································································· 1
Technical specifications ··············································································································· 1
Components ····························································································································· 3
Front panel ······························································································································· 4
Front panel view ·················································································································· 4
LEDs and buttons ················································································································ 6
Ports································································································································· 7
Rear panel ······························································································································· 7
Rear panel view ·················································································································· 7
LEDs ································································································································ 8
Ports································································································································· 9
System board ·························································································································· 10
System board components ·································································································· 10
System maintenance switches ····························································································· 11
DIMM slots ······················································································································· 11
Appendix B Component specifications ··············································· 13
About component model names ·································································································· 13
Processors ····························································································································· 13
Intel processors ················································································································ 13
Jintide-C series processors ································································································· 15
DIMMs ··································································································································· 15
DRAM specifications ·········································································································· 16
DCPMM specifications ······································································································· 16
DIMM rank classification label ······························································································ 16
HDDs and SSDs ······················································································································ 17
Drive specifications ············································································································ 17
Drive LEDs ······················································································································ 26
Drive configurations and numbering ······················································································ 27
PCIe modules ························································································································· 38
Storage controllers ············································································································ 38
NVMe SSD expander modules ····························································································· 48
GPU modules ··················································································································· 48
PCIe Ethernet adapters ······································································································ 54
FC HBAs ························································································································· 56
mLOM Ethernet adapters ··········································································································· 58
Riser cards ····························································································································· 59
Riser card guidelines ·········································································································· 59
PCIe slot numbering ·········································································································· 59
Riser cards for riser connector 1 or 2 ····················································································· 60
Riser cards for riser connector 3 ··························································································· 63
Fans ····································································································································· 65
Fan layout ························································································································ 65
Fan specifications ·············································································································· 66
Power supplies ························································································································ 66
550 W Platinum power supply ······························································································ 66
550 W high-efficiency Platinum power supply ·········································································· 67
800 W Platinum power supply ······························································································ 67
800 W -48 VDC power supply ····························································································· 68
800 W 336 V high-voltage power supply ················································································· 68
850 W high-efficiency Platinum power supply ·········································································· 69
850 W Titanium power supply ······························································································ 69
1200 W Platinum power supply ···························································································· 70
Expander modules ··················································································································· 70
Diagnostic panels····················································································································· 71
Diagnostic panel specifications ····························································································· 71
i
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Advertisement

Table of Contents
loading

Summary of Contents for H3C UniServer R4900 G3 Series

  • Page 1: Table Of Contents

    Contents Appendix A Server specifications ························································ 1     Server models and chassis view ··································································································· 1   Technical specifications ··············································································································· 1   Components ····························································································································· 3   Front panel ······························································································································· 4   Front panel view ·················································································································· 4   LEDs and buttons ················································································································ 6  ...
  • Page 2   Diagnostic panel view ········································································································· 71   LEDs ······························································································································ 72   Fiber transceiver modules ·········································································································· 74   Storage options other than HDDs and SDDs ·················································································· 74   NVMe VROC modules ·············································································································· 75   TPM/TCM modules ·················································································································· 75   Security bezels, slide rail kits, and cable management brackets ························································· 75 Appendix C Managed hot removal of NVMe drives ·······························...
  • Page 3: Appendix A Server Specifications

    Server models and chassis view H3C UniServer R4900 G3 servers are 2U rack servers with two Intel Purley or Jintide-C series processors. They are suitable for cloud computing, IDC, and enterprise networks built based on new generation infrastructure.
  • Page 4 Item 8SFF 8LFF 12LFF 25SFF • 1 × onboard 1 Gbps HDM dedicated network port Network • connection 1 × mLOM Ethernet adapter connector • 6 × USB connectors: 5 × USB 3.0 connectors (one at the server front, two at the server rear, and two on the system board) 1 ×...
  • Page 5: Components

    Components Figure 2 R4900 G3 server components Table 2 R4900 G3 server components Item Description (1) Access panel (2) Power supply air baffle Provides ventilation aisles for power supplies. Generates a chassis open alarm every time the access panel is removed. (3) Chassis-open alarm module The alarms can be displayed from the HDM Web interface.
  • Page 6: Front Panel

    Item Description (11) Riser card Installed in the server to provide additional slots for PCIe modules. (12) Drive cage Encloses drives. Supplies power to the server. It supports hot swapping and 1+1 (13) Power supply redundancy. (14) Riser card blank Installed on an empty riser card connector to ensure good ventilation.
  • Page 7 Figure 3 8SFF front panel (1) VGA connector (optional) (2) USB 2.0 connector (optional) (3) Drive cage bay 1 for 8SFF NVMe SSDs, optical drives, or SATA M.2 SSDs (optional) (4) Drive cage bay 2 for 8SFF SAS/SATA drives or 8SFF NVMe SSDs (5) Drive cage bay 3 for 8SFF SAS/SATA drives or 8SFF NVMe SSDs (optional) (6) Diagnostic panel or serial label pull tab module (optional) (7) USB 3.0 connector...
  • Page 8: Leds And Buttons

    Figure 6 12LFF front panel (1) VGA connector (optional) (2) USB 2.0 connector (optional) (3) Diagnostic panel (optional for the 8LFF SAS/SATA+4LFF NVMe drive configuration) (4) USB 3.0 connector (5) Diagnostic panel (optional for the 12LFF SAS/SATA drive configuration) (6) SAS/SATA or NVMe drives (7) SAS/SATA drives LEDs and buttons The LED and buttons are the same on all server models.
  • Page 9: Ports

    Button/LED Status If a system alarm is present, log in to HDM to obtain more information about the system running status. • Steady green—A link is present on the port. mLOM Ethernet adapter • Flashing green (1 Hz)—The port is receiving or sending data. Ethernet port LED •...
  • Page 10: Leds

    Figure 8 Rear panel components (1) PCIe slots 1 through 3 from the top down (processor 1) (2) PCIe slots 4 through 6 from the top down (processor 2) (3) PCIe slots 7 and 8 from the top down (processor 2) (4) Power supply 2 (5) Power supply 1 (6) BIOS serial port...
  • Page 11: Ports

    Status using the following methods: Press the UID button LED. Enable UID LED from HDM. • Flashing blue: 1 Hz—The firmware is being updated or the system is being managed by HDM. 4 Hz—HDM is restarting. To restart HDM, press the UID button LED for eight seconds.
  • Page 12: System Board

    System board System board components Figure 10 System board components (1) TPM/TCM connector (2) Mezzanine storage controller connector (3) System battery (4) System maintenance switch 1 (5) System maintenance switch 2 (6) System maintenance switch 3 (7) PCIe riser connector 1 (processor 1) (8) mLOM Ethernet adapter connector (9) Ethernet adapter NCSI function connector (10) Mini-SAS port (×8 SATA ports)
  • Page 13: System Maintenance Switches

    System maintenance switches Use the system maintenance switches if you forget HDM username, HDM password, or BIOS password, or need to restore default BIOS settings, as described in Table 7. To identify the location of the switches on the system board, see Figure Table 7 System maintenance switches Item...
  • Page 14 Figure 11 DIMM physical layout...
  • Page 15: Appendix B Component Specifications

    Appendix B Component specifications This appendix provides information about hardware options available for the server at the time of this writing. The hardware options available for the server are subject to change over time. For the most up-to-date hardware options, consult your sales representative. About component model names The model name of a hardware option in this document might differ slightly from its model name label.
  • Page 16 Supported Base Number Cache max. data Model Power UPI speed frequency of cores (L3) links rate of DIMMs 6138 2.0 GHz 125 W 28.00 MB 10.4 GT/s 2666 MHz 6136 3.0 GHz 150 W 24.75 MB 10.4 GT/s 2666 MHz 6134 3.2 GHz 130 W...
  • Page 17: Jintide-C Series Processors

    Supported Base Number Cache max. data Model Power UPI speed frequency of cores (L3) links rate of DIMMs 6140M 2.3 GHz 140 W 24.75 MB 10.4 GT/s 2666 MHz 6134M 3.2 GHz 130 W 24.75 MB 10.4 GT/s 2666 MHz Table 10 Cascade Lake processors Supported Base...
  • Page 18: Dram Specifications

    DRAM specifications Product code Model Type Capacity Data rate Rank 0231AADX DDR4-16G-1Rx4-R-1 RDIMM 16 G 2400 MHz Single-rank 0231AADY DDR4-32G-2Rx4-R-1 RDIMM 32 G 2400 MHz Dual-rank 0231A6SR DDR4-2666-8G-1Rx8-R RDIMM 8 GB 2666 MHz Single-rank 0231A6SP DDR4-2666-16G-1Rx4-R RDIMM 16 GB 2666 MHz Single-rank 0231A6SQ DDR4-2666-16G-2Rx8-R...
  • Page 19: Hdds And Ssds

    To determine the rank classification of a DIMM, use the label attached to the DIMM, as shown Figure Figure 12 DIMM rank classification label Table 11 DIMM rank classification label description Callout Description Remarks Capacity Number of ranks • ×4—4 bits. Data width •...
  • Page 20 Model Form factor Capacity Rate Rotating speed HDD-1.2T-SAS-12G-10K-SFF 1.2 TB 12 Gbps 10000 RPM HDD-1.8T-SAS-12G-10K-SFF 1.8 TB 12 Gbps 10000 RPM HDD-2.4T-SAS-12G-10K-SFF 2.4 TB 12 Gbps 10000 RPM HDD-300G-SAS-12G-10K-LFF-EP 300 GB 12 Gbps 10000 RPM HDD-300G-SAS-12G-15K-LFF-EP 300 GB 12 Gbps 15000 RPM HDD-600G-SAS-12G-10K-LFF-1 600 GB...
  • Page 21 Model Form factor Capacity Rate Rotating speed HDD-8T-SATA-6G-7.2K-LFF-C 8 TB 6 Gbps 7200 RPM HDD-8T-SATA-6G-7.2K-LFF-2 8 TB 6 Gbps 7200 RPM HDD-8T-SATA-6G-7.2K-LFF-3 8 TB 6 Gbps 7200 RPM HDD-8T-SATA-6G-7.2K-LFF-4 8 TB 6 Gbps 7200 RPM HDD-8T-SATA-6G-7.2K-LFF 8 TB 6 Gbps 7200 RPM HDD-10T-SATA-6G-7.2K-LFF 10 TB...
  • Page 22 Model Vendor Form factor Capacity Rate SSD-480G-SATA-6G-SFF-2 Micron 480 GB 6 Gbps SSD-480G-SATA-6G-SFF-3 Samsung 480 GB 6 Gbps SSD-480G-SATA-6G-SFF-4 Samsung 480 GB 6 Gbps SSD-480G-SATA-6G-SFF-5 Micron 480 GB 6 Gbps SSD-480G-SATA-6G-EV-SFF-sa Samsung 480 GB 6 Gbps SSD-480G-SATA-Ny1351-SFF-6 Seagate 480 GB 6 Gbps SSD-480G-SATA-Ny1351-SCL Seagate...
  • Page 23 Model Vendor Form factor Capacity Rate SSD-1.92T-SATA-6G-SFF-2 Samsung 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-SFF-3 Micron 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-EM-SFF-m Micron 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-EV-SFF-i Intel 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-SFF-i Intel 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-SFF-EM-i Intel 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-PM883-SFF Samsung...
  • Page 24 Model Vendor Form factor Capacity Rate SSD-480G-SATA-6G-EV-SCL-i-1 Intel 480 GB 6 Gbps SSD-480G-SATA-6G-EM-SCL-i-2 Intel 480 GB 6 Gbps SSD-480G-SATA-6G-LFF-i-EM Intel 480 GB 6 Gbps SSD-480G-SATA-6G-LFF-EV Intel 480 GB 6 Gbps SSD-480G-SATA-6G-EV-SCL-sa Samsung 480 GB 6 Gbps SSD-480G-SATA-6G-LFF-i Intel 480 GB 6 Gbps SSD-800G-SATA-6G-LFF-i Intel...
  • Page 25 Model Vendor Form factor Capacity Rate SSD-1.92T-SATA-6G-LFF-EV-2 Intel 1.92 TB 6 Gbps SSD-1.92T-SATA-6G-PM883-SCL Samsung 1.92 TB 6 Gbps SSD-1.92T-SATA-PM883-SCL Samsung 1.92 TB 6 Gbps SSD-3.84T-SATA-6G-LFF Micron 3.84 TB 6 Gbps SSD-3.84T-SATA-6G-LFF-1 Samsung 3.84 TB 6 Gbps SSD-3.84T-SATA-6G-LFF-EV Intel 3.84 TB 6 Gbps SSD-3.84T-SATA-6G-LFF-EV-3 Micron...
  • Page 26 Model Vendor Form factor Capacity Interface Rate SSD-2T-NVMe-SFF-i-6 Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-SFF-i-2 Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-SFF-i-3 Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-SFF-i-1 Intel 2 TB PCIe 8 Gbps SSD-3.2T-NVMe-EM-SFF-mbl Memblaze 3.2 TB PCIe 8 Gbps SSD-3.2T-NVMe-EM-SFF-i Intel...
  • Page 27 Model Vendor Form factor Capacity Interface Rate SSD-1.92T-NVMe-EV-SCL-sa Samsung 1.92 TB PCIe 8 Gbps SSD-2T-NVMe-LFF Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-LFF-1 Memblaze 2 TB PCIe 8 Gbps SSD-2T-NVMe-LFF-i-3 Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-LFF-i-2 Intel 2 TB PCIe 8 Gbps SSD-2T-NVMe-LFF-i-1 Intel...
  • Page 28: Drive Leds

    NVMe SSD PCIe accelerator module Form Link Model Vendor Capacity Interface Rate factor width SSD-NVME-375G-P4800X Intel HHHL 375 GB PCIe 8 Gbps ×4 SSD-NVME-750G-P4800X Intel HHHL 750 GB PCIe 8 Gbps ×4 SSD-NVME-1.6T-EM-2 SHANNON 1.6 TB PCIe 8 Gbps ×8 SSD-1.6T-NVME-PM1725b Samsung HHHL...
  • Page 29: Drive Configurations And Numbering

    Fault/UID LED status Present/Active LED status Description Steady green/Flashing green The drive is operating correctly and is Steady blue (4.0 Hz) selected by the RAID controller. The drive is performing a RAID migration or Flashing green (4.0 Hz) rebuilding, or the system is reading or writing data to the drive.
  • Page 30 Table 14 Drive, storage controller, and NVMe SSD expander module configurations (8SFF server) Drive backplane and drive NVMe SSD expander Drive configuration Storage controller expander module module • Embedded RSTe 8SFF • Mezzanine (8 front SFF SAS/SATA • drives in drive cage bay Standard in PCIe slot 2 or 6 •...
  • Page 31 Drive backplane and drive NVMe SSD expander Drive configuration Storage controller expander module module slots 2 and 5 (8 front SFF SAS/SATA drives in drive cage bay 1 + 16 front SFF NVMe 2 × 8-port NVMe SSD drives in drive cage Mezzanine expander modules in PCIe bays 2 and 3)
  • Page 32 Figure 15 Drive numbering for 16SFF drive configurations (8SFF server) Figure 16 Drive numbering for the 24SFF drive configuration (8SFF server) Figure 17 Drive numbering for the 24SFF NVMe drive configuration (8SFF server) 25SFF server Table 16 presents the drive configurations available for the 25SFF server and their compatible types of storage controllers and NVMe SSD expander modules.
  • Page 33 Drive backplane NVMe SSD and drive Drive configuration Storage controller expander module expander module 25SFF • Mezzanine (25 front SFF SAS/SATA • Standard in PCIe slot 6 drives) BP2-25SFF-2U-G3 • Mezzanine 25SFF drive 27SFF • Standard in PCIe slot 6 backplane (25 front SFF SAS/SATA The rear drives must be...
  • Page 34 Figure 20 Drive numbering for the 29SFF (25 front+4 rear) drive configuration (25SFF server) Figure 21 Drive numbering for the 29SFF (25 front+4 rear)+2LFF drive configuration (25SFF server) 8LFF server The 8LFF server supports only one drive configuration. Table 18 presents this drive configuration and its compatible types of storage controllers and NVMe SSD expander modules.
  • Page 35 12LFF server Table 19 presents the drive configurations available for the 12LFF server, their compatible types of storage controllers and NVMe SSD expander modules, and drive numbering schemes. Table 19 Drive configurations supported by the 12LFF server Drive NVMe SSD backplane and Drive Drive...
  • Page 36 Drive NVMe SSD backplane and Drive Drive Storage controller expander drive expander configuration numbering module module 16LFF+4SFF (12 front and 4 rear Mezzanine Figure LFF SAS/SATA drives + 4 rear SFF SAS/SATA drives) 1 × 4-port NVMe SSD expander Embedded RSTe module in PCIe slot 12LFF 1 ×...
  • Page 37 Drive NVMe SSD backplane and Drive Drive Storage controller expander drive expander configuration numbering module module Mezzanine 12LFF+2SFF Standard in PCIe (12 front LFF slot 6 Figure SAS/SATA drives + The rear drives must 2 rear SFF be connected to the SAS/SATA drives) drive backplane.
  • Page 38 Figure 23 Drive numbering for the 12LFF drive configuration (12LFF server) Figure 24 Drive numbering for the 12LFF+2SFF drive configuration (12LFF server) Figure 25 Drive numbering for the 12LFF+4SFF drive configuration (12LFF server) Figure 26 Drive numbering for the 14LFF (12 front+2 rear) drive configuration (12LFF server)
  • Page 39 Figure 27 Drive numbering for the 16LFF (12 front+4 rear) drive configuration (12LFF server) Figure 28 Drive numbering for the 14LFF (12 front+2 rear)+2SFF drive configuration (12LFF server) Figure 29 Drive numbering for the 14LFF (12 front+2 rear)+4SFF drive configuration (12LFF server)
  • Page 40: Pcie Modules

    Figure 30 Drive numbering for the 16LFF (12 front+4 rear)+2SFF drive configuration (12LFF server) Figure 31 Drive numbering for the 16LFF (12 front+4 rear)+4SFF drive configuration (12LFF server) PCIe modules Typically, the PCIe modules are available in the following standard form factors: •...
  • Page 41 failure occurs, the supercapacitor provides power for a minimum of 20 seconds. During this interval, the storage controller can transfer data from DDR memory to the flash card, where the data remains indefinitely or until the controller retrieves the data. If the storage controller contains a built-in flash card, you can order only a supercapacitor.
  • Page 42 Item Specifications Connectors One ×8 mini-SAS connector Number of internal ports 8 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface PCIe3.0 ×8 RAID levels 0, 1, 10 Built-in cache memory •...
  • Page 43 Item Specifications RAID levels Not supported Built-in cache memory • SAS HDD • SAS SSD Supported drives • SATA HDD • SATA SSD Power fail safeguard module Not supported Firmware upgrade Online upgrade HBA-LSI-9311-8i Item Specifications Type Standard storage controller Form factor Connectors One ×8 mini-SAS-HD connector...
  • Page 44 Item Specifications • SATA HDD • SATA SSD Power fail safeguard module Not supported Firmware upgrade Online upgrade RAID-L460-M4 Item Specifications Type Mezzanine storage controller Dimensions 137 × 103 mm (5.39 × 4.06 in) Connectors One ×8 mini-SAS-HD connector Number of internal ports 8 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0...
  • Page 45 Item Specifications • SATA HDD • SATA SSD Flash-PMC-G2 Power fail safeguard module The power fail safeguard module is optional. Built-in flash card Supercapacitor connector The supercapacitor connector is on the flash card of the power fail safeguard module. Firmware upgrade Online upgrade RAID-P430-M2 Item...
  • Page 46 Item Specifications Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface PCIe3.0 ×8 RAID levels 0, 1, 5, 6, 10, 50, 60 Built-in cache memory 2 GB internal cache module (DDR4-2133 MHz) • SAS HDD • SAS SSD Supported drives •...
  • Page 47 Item Specifications Connectors One ×8 mini-SAS-HD connector Number of internal ports 8 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface PCIe3.0 ×8 RAID levels 0, 1, 5, 6, 10, 50, 60 Built-in cache memory 2 GB internal cache module (DDR4-2133 MHz) •...
  • Page 48 RAID-LSI-9361-8i(1G)-A1-X Item Specifications Type Standard storage controller Form factor Connectors One ×8 mini-SAS-HD connector Number of internal ports 8 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface PCIe3.0 ×8 RAID levels 0, 1, 5, 6, 10, 50, 60 Built-in cache memory...
  • Page 49 Item Specifications The supercapacitor connector is on the flash card of the power fail safeguard module. Firmware upgrade Online upgrade RAID-LSI-9460-8i(2G) Item Specifications Type Standard storage controller Form factor Connectors One ×8 mini-SAS-HD connector Number of internal ports 8 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface...
  • Page 50: Nvme Ssd Expander Modules

    Item Specifications The supercapacitor is optional. Built-in flash card Available Supercapacitor connector Available Firmware upgrade Online upgrade RAID-LSI-9460-16i(4G) Item Specifications Type Standard storage controller Form factor Connectors Four ×4 mini-SAS-HD connectors Number of internal ports 16 internal SAS ports (compatible with SATA) Drive interface 12 Gbps SAS 3.0 or 6 Gbps SATA 3.0 PCIe interface...
  • Page 51 Item Specifications Maximum power consumption 120 W • 1 × DVI-I connector Display connectors • 2 × DP connectors Memory size 8 GB GDDR5 Memory bus width 256 bits Memory bandwidth 192 Gbps Power connector Available Required chassis air baffle Standard chassis air baffle GPU-M60-1-X Item...
  • Page 52 Item Specifications Form factor FH3/4FL, dual-slot wide Maximum power consumption 250 W Display connectors Memory size 24 GB GDDR5s Memory bus width 384 bits Memory bandwidth 346 Gbps Power connector Available Required chassis air baffle Standard chassis air baffle GPU-P100 Item Specifications PCIe interface...
  • Page 53 Item Specifications Form factor FH3/4FL, dual-slot wide Maximum power consumption 250 W Display connectors Memory size 32 GB HBM2 Memory bus width 4096 bits Memory bandwidth 900 Gbps Power connector Available Required chassis air baffle GPU-dedicated chassis air baffle GPU-T4 Item Specifications PCIe interface...
  • Page 54 Item Specifications Form factor FH3/4FL, dual-slot wide Maximum power consumption 300 W • 1 × DVI-I connector Display connectors • 2 × DP connectors Memory size 24 GB GDDR5 Memory bus width 384 bits Memory bandwidth 480 Gbps Power connector Available Required chassis air baffle Standard chassis air baffle...
  • Page 55 Item Specifications Form factor FH3/4FL, dual-slot wide Maximum power consumption 250 W Display connectors Memory size 32 GB GDDR5s Memory bus width 128 bits Memory bandwidth 332 Gbps Power connector Available Required chassis air baffle Standard chassis air baffle GPU module and riser card compatibility PCIe riser Riser card PCIe slot...
  • Page 56: Pcie Ethernet Adapters

    PCIe riser Riser card PCIe slot Available GPU modules connector • GPU-P100 • GPU-V100-32G Slot 2 or 5 RC-FHHL-2U-G3-1 Connector 1 or 2 • GPU-V100 Slot 3 or 6 Not supported Slot 1 or 4 • GPU-P4-X • GPU-T4 RC-3GPU-R4900-G3 Connector 1 or 2 Slot 2 or 5 •...
  • Page 57 NIC-10GE-2P-530F-B2- SFP+ 10 Gbps PCIe2.0 ×8 supported NIC-620F-B2-25Gb-2P-1 SFP28 25 Gbps PCIe3.0 ×8 Supported 10/100/1000 NIC-GE-4P-360T-B2-1-X RJ-45 PCIe2.0 ×4 Mbps supported NIC-BCM957416-T-B-10 RJ-45 10 Gbps PCIe3.0 ×8 Gb-2P supported NIC-BCM957302-F-B-10 SFP+ 10 Gbps PCIe3.0 ×8 Gb-2P supported NIC-BCM957412-F-B-10 SFP+ 10 Gbps PCIe3.0 ×8 Gb-2P supported...
  • Page 58: Fc Hbas

    NIC-MCX4121A-F-B-25 SFP28 25 Gbps PCIe3.0 ×8 Gb-2P supported NIC-MCX512A-ACAT-F- SFP28 25 Gbps PCIe3.0 ×8 2*25Gb supported NIC-XXV710-F-B-25Gb- SFP28 25 Gbps PCIe3.0 ×8 supported PCIe3.0 NIC-OPA-100Gb-1P QSFP28 100 Gbps ×16 supported NIC-10/25Gb-2P-640FL SFP28 25 Gbps PCIe3.0 ×8 FLOM Supported R-SFP28 NIC-iETH-PS225-H16 SFP28 25 Gbps PCIe3.0 ×8...
  • Page 59 Item Specifications Connector SFP+ Data rate 16 Gbps HBA-8Gb-LPe12000-1P-1-X Item Specifications Form factor Ports Connector SFP+ Data rate 8 Gbps HBA-8Gb-LPe12002-2P-1-X Item Specifications Form factor Ports Connector SFP+ Data rate 8 Gbps HBA-16Gb-LPe31000-1P-1-X Item Specifications Form factor Ports Connector SFP+ Data rate 16 Gbps HBA-16Gb-LPe31002-2P-1-X...
  • Page 60: Mlom Ethernet Adapters

    Item Specifications Data rate 32 Gbps FC-HBA-LPe32002-32Gb-2P-X Item Specifications Form factor Ports Connector SFP+ Data rate 32 Gbps FC-HBA-QLE2740-32Gb-1P Item Specifications Form factor Ports Connector SFP+ Data rate 32 Gbps FC-HBA-QLE2742-32Gb-2P Item Specifications Form factor Ports Connector SFP+ Data rate 32 Gbps mLOM Ethernet adapters In addition to mLOM Ethernet adapters, the server also supports PCIe Ethernet adapters (see...
  • Page 61: Riser Cards

    NIC-10GE-2P-560T-L2 Item Specifications Dimensions 128 × 68 mm (5.04 × 2.68 in) Ports Connector RJ-45 Data rate 1/10 Gbps Bus type 10G-KR ×2 NCSI Supported NIC-10GE-2P-560F-L2 Item Specifications Dimensions 128 × 68 mm (5.04 × 2.68 in) Ports Connector SFP+ Data rate 10 Gbps Bus type...
  • Page 62: Riser Cards For Riser Connector 1 Or 2

    Riser cards for riser connector 1 or 2 If a riser card can be installed on riser connector 1 or 2, the slot numbers of its PCIe slots are presented in the m/n format in this document. • The m argument represents the PCIe slot number on connector 1. •...
  • Page 63 Item Specifications Maximum power supplied per PCIe slot 75 W Figure 34 PCIe slots on the RC-3GPU-R4900-G3 riser card (1) PCIe slot 1/4 (2) PCIe slot 2/5 (3) PCIe slot 3/6 RC-FHHL-2U-G3-1 Item Specifications • Connector 1 PCIe riser connector •...
  • Page 64 RC-GPU/FHHL-2U-G3-1 Item Specifications • Connector 1 PCIe riser connector • Connector 2 • Slot 2/5, PCIe3.0 ×16 (16, 8, 4, 2, 1) • Slot 3/6, PCIe3.0 ×8 (8, 4, 2, 1) PCIe slots NOTE: The numbers in parentheses represent link widths. FHHL (only slot 2/5 supports single-wide and double-wide GPU Form factors of PCIe modules modules)
  • Page 65: Riser Cards For Riser Connector 3

    Figure 37 PCIe slots on the RS-3*FHHL-R4900 riser card (1) PCIe slot 1/4 (2) PCIe slot 2/5 (3) PCIe slot 3/6 Riser cards for riser connector 3 RC-2*LP-2U-G3 Item Specifications PCIe riser connector Connector 3 • Slot 7, PCIe3.0 ×16 (16, 8, 4, 2, 1) •...
  • Page 66 RC-2GPU-R4900-G3 Item Specifications PCIe riser connector Connector 3 • Slot 7: PCIe3.0 ×16 (16, 8, 4, 2, 1) • Slot 8: PCIe3.0 ×8 (8, 4, 2, 1) PCIe slots NOTE: The numbers in parentheses represent link widths. Available PCIe modules GPU-P4-X, GPU-T4, and GPU-MLU100-D3 GPU modules Maximum power supplied per PCIe slot 75 W...
  • Page 67: Fans

    RC-GPU/FHHL-2U-G3-2 Item Specifications PCIe riser connector Connector 3 • Slot 7: PCIe3.0 ×16 (16, 8, 4, 2, 1) • Slot 8: PCIe3.0 ×8 (8, 4, 2, 1) PCIe slots NOTE: The numbers in parentheses represent link widths. • Slot 7: FHFL (including single-wide and double-wide GPU modules) Form factors of PCIe modules •...
  • Page 68: Fan Specifications

    Figure 42 Fan layout Fan specifications Item Specifications Model FAN-2U-G3 Form factor 2U standard fan Power supplies The power supplies have an overtemperature protection mechanism. A power supply stops working when an overtemperature occurs and automatically recovers when the overtemperature condition is removed.
  • Page 69: 550 W High-Efficiency Platinum Power Supply

    Item Specifications Operating humidity 5% to 90% Maximum altitude 5000 m (16404.20 ft) Redundancy 1+1 redundancy Hot swappable Cold backup 550 W high-efficiency Platinum power supply Item Specifications Model DPS-550W-12A • 100 VAC to 240 VAC @ 50/60 Hz (10 A receptacle) Rated input voltage range •...
  • Page 70: 800 W -48 Vdc Power Supply

    Item Specifications Maximum altitude 5000 m (16404.20 ft) Redundancy 1+1 redundancy Hot swappable Cold backup 800 W –48 VDC power supply Item Specifications Model DPS-800W-12A-48V Rated input voltage range –48 VDC to –60 VDC Maximum rated input current 20.0 A @ –48 VDC to –60 VDC Maximum rated output power 800 W Efficiency at 50 % load...
  • Page 71: 850 W High-Efficiency Platinum Power Supply

    Item Specifications Redundancy 1+1 redundancy Hot swappable Cold backup 850 W high-efficiency Platinum power supply Item Specifications Model DPS-850W-12A • 100 VAC to 240 VAC @ 50/60 Hz (10 A receptacle) Rated input voltage range • 192 VDC to 288 VDC (240 HVDC power source) •...
  • Page 72: 1200 W Platinum Power Supply

    Item Specifications Hot swappable Cold backup 1200 W Platinum power supply Item Specifications Model PSR1200-12A • 100 VAC to 127 VAC @ 50/60 Hz (1000 W) • 200 VAC to 240 VAC @ 50/60 Hz (1200 W) Rated input voltage range •...
  • Page 73: Diagnostic Panels

    Model Specifications HDD-Cage-8SFF-2U-3 Front 8SFF SAS/SATA drive cage module for drive cage bay 3 HDD-Cage-8SFF-2U-NVMe-2 Front 8SFF NVMe drive cage module for drive cage bay 2 HDD-Cage-8SFF-2U-2 Front 8SFF SAS/SATA drive cage module for drive cage bay 2 HDD-Cage-8SFF-2U-NVMe-1 Front 8SFF NVMe drive cage module for drive cage bay 1 Diagnostic panels Diagnostic panels provide diagnostics and troubleshooting capabilities.
  • Page 74: Leds

    LEDs POST LED LED status Error code Description Code for the current Steady green POST phase (in the The server is performing POST without detecting any error. range of 00 to 99) Code for the current The POST process encountered an error and stopped in the Flashing red POST phase (in the displayed phase.
  • Page 75 Error code Faulty item Mezzanine storage controller power Reserved mLOM Ethernet adapter NOTE: If the error code field displays 11 and any other code alternatively, replace the faulty item other than the system board. If the issue persists, replace the system board. Processor 1 (processor) Processor 2...
  • Page 76: Fiber Transceiver Modules

    Error code Faulty item System board VPP processor 1 DEF voltage System board VDDQ processor 1 ABC voltage System board VDDQ processor 1 DEF voltage System board VTT processor 1 ABC voltage System board VTT processor 1 DEF voltage System board VPP processor 1 ABC voltage System board VPP processor 1 DEF voltage System board VDDQ processor 2 ABC voltage System board VDDQ processor 2 DEF voltage...
  • Page 77: Nvme Vroc Modules

    NVMe VROC modules Model RAID levels Compatible NVMe drives NVMe-VROC-Key-S 0, 1, 10 All NVMe drives NVMe-VROC-Key-P 0, 1, 5, 10 All NVMe drives NVMe-VROC-Key-i 0, 1, 5, 10 Intel NVMe drives TPM/TCM modules Trusted platform module (TPM) is a microchip embedded in the system board. It stores encryption information (such as encryption keys) for authenticating server hardware and software.
  • Page 78: Appendix C Managed Hot Removal Of Nvme Drives

    Appendix C Managed hot removal of NVMe drives Managed hot removal of NVMe drives enables you to remove NVMe drives safely while the server is operating. Table 23 to determine the managed hot removal method depending on the VMD status and the operating system.
  • Page 79: Performing A Managed Hot Removal In Linux

    Figure 44 Removing an NVMe drive Observe the Fault/UID LED on the drive. If the Fault/UID LED turns steady blue and the drive is removed from the Devices list, remove the drive from the server. For more information about the removal procedure, see "Replacing an NVMe drive." Performing a managed hot removal in Linux ®...
  • Page 80: Performing A Managed Hot Removal From The Intel Asm Web Interface

    Figure 45 Identifying the drive letter of the NVMe drive to be removed Execute the ledctl locate=/dev/drive_letter command to turn on the Fault/UID LED on the drive. The drive_letter argument represents the drive letter, for example, nvme0n1. Execute the echo 1 > /sys/block/drive_letter/device/device/remove command to unmount the drive from the operating system.
  • Page 81 Figure 47 Viewing operating NVMe drives Click the light bulb icon to turn on the Fault/UID LED on the drive, as shown in Figure Figure 48 Turning on the drive Fault/UID LED After the Fault/UID LED for the NVMe drive turns steady blue, click the removal icon, as shown Figure...
  • Page 82 Figure 49 Removing an NVMe drive In the confirmation dialog box that opens, click Yes. Figure 50 Confirming the removal Remove the drive from the server. For more information about the removal procedure, see "Replacing an NVMe drive."...
  • Page 83: Appendix D Environment Requirements

    Appendix D Environment requirements About environment requirements The operating temperature requirements for the server vary depending on the server model and hardware configuration. When the general and component-based requirements conflict, use the component-based requirement. Be aware that the actual maximum operating temperature of the server might be lower than what is stated because of poor site cooling performance.
  • Page 84 If a single fan fails, the maximum server operating temperature drops by 5°C (41°F) and cannot exceed 35°C (95°F). NOTE: All maximum server operating temperature values are provided on the basis that the fans are installed as needed and operating correctly. For more information about fan configurations, see the guidelines in "Installing fans."...
  • Page 85: 8Sff Server With A 16Sff/24Sff Drive Configuration

    8SFF server with a 16SFF/24SFF drive configuration Table 25 to determine the maximum operating temperature of the 8SFF server with a 16SFF/24SFF drive configuration. A maximum server operating temperature applies if the server contains any options in its matching hardware option list. If a single fan fails, the maximum server operating temperature drops by 5°C (41°F) and cannot exceed 35°C (95°F).
  • Page 86: 25Sff Server With Any Drive Configuration

    Maximum server operating Hardware options temperature any of the following drive configurations: 16SFF SAS/SATA. 16SFF (8SFF SAS/SATA+8SFF NVMe, or 16SFF NVMe) without NVMe drives that have a 3.2TB capacity (or larger). • DCPMMs. • Samsung NVMe drives. • Rear drives. •...
  • Page 87: 8Lff Server With Any Drive Configuration

    Maximum server operating Hardware options temperature • GPU-P100. • GPU-V100-32G. • GPU-V100. Any of the following GPU modules used with 165W (or higher) processors: • GPU-K80-1. 27°C (80.6°F) • GPU-M60-1-X. • GPU-P40-X. Any of the following GPU modules used with less than 165W processors: •...
  • Page 88: 12Lff Server With Any Drive Configuration

    Table 27 Temperature requirements for the 8LFF server with any drive configuration Maximum server Hardware options operating temperature GPU modules: • GPU-P100. 30°C (86°F) • GPU-V100-32G. • GPU-V100. Any of the following GPU modules used with 165W (or higher) processors: •...
  • Page 89 Maximum server operating Hardware options temperature • GPU-M60-1-X. • GPU-P40-X. • GPU modules: GPU-P100. GPU-V100-32G. GPU-V100. • 25°C (77°F) Any of the following GPU modules used with less than 165W processors: GPU-K80-1. GPU-M60-1-X. GPU-P40-X. • DCPMM. • Samsung NVMe drives. •...
  • Page 90: Appendix E Product Recycling

    Appendix E Product recycling New H3C Technologies Co., Ltd. provides product recycling services for its customers to ensure that hardware at the end of its life is recycled. Vendors with product recycling qualification are contracted to New H3C to process the recycled hardware in an environmentally responsible way.
  • Page 91: Appendix F Glossary

    An Ethernet adapter, also called a network interface card (NIC), connects the server to the adapter network. Fast Intelligent Scalable Toolkit provided by H3C for easy and extensible server FIST management. It can guide users to configure a server quickly with ease and provide an API interface to allow users to develop their own management tools.
  • Page 92 Item Description A locking bezel mounted to the front of a server to prevent unauthorized access to Security bezel modules such as hard drives. A unit of measure defined as 44.45 mm (1.75 in) in IEC 60297-1. It is used as a measurement of the overall height of racks, as well as equipment mounted in the racks.
  • Page 93: Appendix G Acronyms

    DRAM Dynamic Random Access Memory FIST Fast Intelligent Scalable Toolkit Graphics Processing Unit Host Bus Adapter Hard Disk Drive H3C Device Management Internet Data Center Keyboard, Video, Mouse Large Form Factor LRDIMM Load Reduced Dual Inline Memory Module mLOM Modular LAN-on-Motherboard...
  • Page 94 Acronym Full name RAID Redundant Array of Independent Disks RDIMM Registered Dual Inline Memory Module Serial Attached Small Computer System Interface SATA Serial ATA Secure Digital Secure Diagnosis System Small Form Factor Solid State Drive Trusted Cryptography Module Thermal Design Power Trusted Platform Module Unit Identification Ultra Path Interconnect...

Table of Contents