Page 1
Installation and Commissioning Instructions LZ 1 - 2,5 A - (KNX) - N - 24 v Dc atural veNtilatioN coNtrol uNit...
Page 2
ontents Abbreviations Warning and Safety Symbols Target Groups, Intended Use Safety Instructions, Guidelines and Standards 3 - 8 2,5 A Circuit diagram: LZ 1 - 2,5 A - (KNX) - Natural ventilation control unit 24 V DC Storage and Demounting Disposal Warranty and After-Sales Service Liability...
Page 3
reliminary remark bbreviatioNs Index of abbreviations Scale units These abbreviations are used consistently throughout this instruction. °C Degree Celsius Unless stated differently, all dimensions indicated in this document are in mm. Amperes General tolerances in accordance with DIN ISO 2768-m. Amp-hours Surface mounting Kilogram...
reliminary remark arget group These instructions are intended for personnel trained in they are supervised by a person who is electrical engineering and skilled operators of systems for responsible for the safety or were instruc- natural ventilation via windows, who are knowledgeable ted by him on the usage of this equip- of operating modes and remaining risks of the system.
reliminary remark The need for a risk assessment at the installation site • the installation height of the drive and lower edge due to reasonably foreseeable misuse. of casement < 2,5 m above the floor A risk assessment in accordance with the Machinery and one of the following conditions: Directive 2006 / 42 / EG by activation of the power- •...
afety instruCtions We recommend using exclusively sys- require the express written consent of tem components by a , because . Utilization of applications and umüller umüller their compatibility is carefully checked components not expressly authorized by in the factory. a shall not assume are considered as unintended umüller...
afety instruCtions Cables must be laid such way that they cannot Before working on the system it must be com- be sheared off, twisted or bent during operati- pletely disconnected from the power supply on. It is recommended to perform an insulati- and emergency power supply (e.g.
afety instruCtions Declaration of Conformity uiDeliNes aND taNDarDs The control device is manufactured and inspected for its The most recent state of country-specific laws, regulations, intended use in accordance with the European guidelines. provisions and standards must absolutely be observed du- The respective Declaration of Conformity is on hand.
Page 9
irCuit iagram ircuit Diagram 2,5 A LZ 1 - 2,5 A - (KNX) - N 24 v Dc atural veNtilatioN coNtrol uNit LZ 1 - 2,5 A - Natural ventilation control unit 24 V DC Only connect when disconnected from the mains Only 24 V DC drives may be connected.
isPosal arranty emouNtiNg aND DismaNtliNg arraNty aND ustomer service The Control Unit must be stored only in locations protected from mois- In principle, our: ture, severe contamination and temperature fluctuations (not above „General Terms for the Supply of Products and Services of the 30°C).
Page 11
ertificate aND eclaratioN of oNformity The proof of the application of a quality management We declare under our sole responsibility that the product system is for company: described under "Data sheet" is in conformity with the GmbH umüLLer umAtic following directives: according to the certification basis DIN EN 9001 as well the "Declaration of Incorporation and Conformity"...
Need help?
Do you have a question about the LZ1-2,5A-KNX and is the answer not in the manual?
Questions and answers