DIAGNOSTIC MESSAGES

48
No message on display.
Power has been cut off to the spa.
The control panel will be disabled until power re-
turns. Time of day will be preserved for 30 days with
a battery back-up on EL8000 and EL 5000 systems.
EL1000 and some EL2000 systems reset the time of
day on each power-up. Pool settings are preserved
on all systems
"Overheat" - The pool has shutdown. On some sys-
tems, an alarm may sound. One of the sensors has
detected 118ºF (approximately 47.8ºC) at the heater.
DO NOT ENTER THE WATER. Remove the spa
cover and allow water to cool. Once the heater has
cooled, reset by pushing any button. If pool does
not reset, shut off the power to the pool and call your
dealer or service organization
"Overheat" - The pool has shutdown. One of the
sensors has detected that the pool water is 110ºF
(approximately 43.3ºC).
DO NOT ENTER THE WATER. Remove the pool
cover and allow water to cool. At 107ºF (approxi-
mately 41.7ºC), the pool should automatically reset.
If pool does not reset, shut off the power to the pool
and call your dealer or service organization
"Ice" - Potential freeze condition detected.
No action required. The pumps and the blower will
automatically activate regardless of pool status.
Pool is shutdown. The sensor that is plugged into
the Sensor "A" jack is not working
If the problem persists, contact your dealer or ser-
vice organization. (May appear temporarily in an
overheat situation and disappear when the heater
cools).
Pool is shutdown. The sensor that is plugged into
the Sensor "B" jack is not working
If the problem persists, contact your dealer or
service organization. (May appear temporarily in an
overheat situation and disappear when the heater
cools).