Do not flue into natural draught flues or
fireplaces, this unit can only be used with a
Rinnai flue kit.
(A flue kit is available to flue right through to
the rear of most fireplaces Use this kit when
the heater is going to be installed in front of a
fireplace.)
Do not flue unit into other rooms.
Flue terminal must be outside.
Flue may be p o s i t i o n e d directly under
opening windows. with a minimum clearance
of 150 rnm.
Flue sizes :
6 flue lengths are available (Sold Separately)
AA flue suits walls 75-1 15mm
A flue suits walls
11
5-240rnm
B flue suits walls 240-400mrn
C flue suits walls 400-600mm
D flue suits walls 600-800mm
E flue suits walls 800-1 000mm
For information on special extra long flues,
contact Rinnai.
Co-ax internal wall flues are also available.
Separate instructions are supplied with co-ax
flue kits.
Standard installation of flue manifold.
Diagram below shows minimum clearances
and distances from obstructions.
Also check AG601 and 1 or local regulations.
7
-
1
Flammable
I
I
Side Clearances.