SEM QUICK TIPS

1
2
3
Z-WAVE
CONTACT INFORMATION
If you've completed the steps above, but are experiencing difficulties with
SEM installation, please visit www.alarm.com/supportcenter or contact
Alarm.com Technical Support at 866-834-0470 and we'll be happy to
assist you further.
SEM INSTALLATION GUIDE 181005
SET KEYPAD ADDRESS
Ensure the SEM's keypad address is enabled in VISTA
programming. The default keypad address is 23 enabled
in *196 VISTA programming.
See Step 3 for additional addresses and their
corresponding programming sections.
WIRING IS CORRECT
[PANEL] GREEN DATA IN
[PANEL] YELLOW DATA OUT
SEM is powered from 12V battery with included
connector and fuse
INSTALLER CODE SYNCED WITH SEM
The Installer Code entered during account creation is
applied to the SEM during the initialization process.
If the system still fails to initiate a zone scan, set the
Installer Code to a new value and power cycle.
If the customer has existing Z-Wave devices, they will
need to be deleted from the previous controller and
added to the SEM. Tuxedo Touch users will need to choose
between leaving devices enrolled on the Tuxedo for local
control or enrolling them on the SEM to enable remote
control capability.
| Copyright © 2018 Alarm.com. All rights reserved.
[SEM] GREEN (OUT)
[SEM] YELLOW (IN)