STEP 3: ENABLE KEYPAD ADDRESS

ENABLING KEYPAD 8 DEVICE ADDRESS 23
The SEM communicates with the VISTA panel as if it is a keypad.
By default, the SEM will use Keypad 8 Device Address 23 to
communicate. Address 23 must be enabled via panel programming.
To do this, enter programming and select *196 + [1] + *99 at the keypad.
IF ADDRESS 23 IS ALREADY IN USE
In most cases, Address 23 will be available. If another keypad is already
connected to Address 23, you will need to manually select a different
keypad address. You can do this by using the DIP switches on the SEM,
as pictured below.
1.
Identify an available keypad address.
2.
Using the chart below, change the DIP switches on
the SEM to match the corresponding keypad address.
3.
Enable the address by entering the corresponding
VISTA programming command at the panel.
Keypad
Address
17
None—all OFF
18
Switch 4 ON, others OFF
19
Switch 3 ON, others OFF
20
Switch 3 and 4 ON, others OFF
21
Switch 2 ON, others OFF
22
Switch 2 and 4 ON, others OFF
23
Switch 2 and 3 ON, others OFF
If the correct keypad address is not enabled, repeated
reports of Panel Malfunction will be shown in the Event
History on the Partner Portal or MobileTech once the
SEM is powered on and connects to the network.
6
DIP Switch
Setting
VISTA
Programming Menu
*190
*191
*192
*193
*194
*195
*196