13 | Inspiration and help
Error report
Data communication failed
Service (E) 34.64
Data communication failed
Service (E) 34,400
Data communication failed
Service (E) 41
Service (E) 50
Initialise timer
Service (E) 51
Battery failed
Service (E) 52.1
Cabinet light failed
Service (E) 52.2
Cabinet light failed
Service (E) 72
The safety temperature limiter
has initialised
52 / 64
Cause
The internal data communication is faulty.
The internal data communication is faulty.
The steam injection nozzle or the steam
injection pipe has scale.
The real time clock on the CPU is not
initialised. Set the date and time.
The battery is defective.
The cooking cabinet lighting is not
working correctly.
The cooking cabinet lighting is not
working correctly.
The activation temperature of a
temperature probe has been exceeded.
Cooking possible
Yes
Yes
The steam injection function is
not available.
Yes
Yes
Yes
Yes
No