Cisco ASR 1000 Series Replacing page 108

Removing and replacing frus from the routers
Table of Contents

Advertisement

Removing and Replacing the Cisco ASR 1001 Router Power Supplies
The following figure shows both the AC and DC power supplies for the Cisco ASR 1001 Router.
Figure 73: Cisco ASR 1001 Router AC Power Supply and DC Power Supply
1
AC and DC power supply fasteners
2
AC power supply inlet
3
DC power supply negative (-) connection
4
DC power supply positive (+) connection
This section contains the following topics:
Warning
The covers are an integral part of the safety design of the product. Do not operate the unit without the covers
installed. Statement 1077
Warning
When you install the unit, the ground connection must always be made first and disconnected last. Statement
1046
Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement
1030
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
108
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
5
DC power supply ground symbol
6
DC power supply terminal block connection
7
AC and DC power supply handles