10.1.1. Check Power

10.1.1.1. Base Unit
Is the AC Adaptor inserted into AC outlet? (*1)
Is output voltage of AC adaptor 5.5 V?
YES
Check VDD1(1.8 V) :Test point (VDD1)
OK
RSTN: Reset = "High"?
YES
Check Xtal CLK=10.368 MHz?
YES
Check BBIC.
Cross Reference:
Power Supply Circuit/Reset Circuit (P.14)
10.1.1.2. Handset
Is the battery inserted to BATT+ and BATT-?
YES
Is the voltage of TP-VBAT 2.3 V more?
YES
Is the voltage of TP 1.8V about 1.8 V?
YES
Does BBIC (IC1: 49) oscillate at 10.368 MHz?
YES
Check BBIC (IC1).
Cross Reference:
Power Supply Circuit/Reset Circuit (P.22)
All manuals and user guides at all-guides.com
NO
NO
NO
NO
NO
NO
NO
31
KX-PRL260/KX-PRL262/KX-PRD260/KX-PRD262/KX-PRLA20
AC Adaptor.
Check
Check Power Supply Circuit.
Check Reset Circuit.
Check X501.
Note:
BBIC is IC501.
(*1) Refer to Specifications (P.7) for part number and
supply voltage of AC adaptor.
(*2) Refer to Circuit Board (Base Unit_Main) (P.74).
Check the battery and around BATT+ and
BATT- are not shorted.
Check Power Supply Circuit/Reset Circuit.
Check X1, C52, C53.