• Wine-Mate split cooling systems VINO2500-8500SSH are designed and used
to provide a cold temperature between 50~65
room at a normal environment.
• The wine room will maintain humidity of 50~70% RH even when the
environment becomes dry and humid. These temperatures and humilities are
optimized for long term storage of wine.
• SSH units consist of a condensing unit and an evaporator unit, and they are
connected by a liquid line and an insulated suction line.
• SSH condensing units can be located away from the evaporator units and
wine cellars as far as 50 ft, which will bring you quiet operation.
• The SSH evaporator units are designed to provide chilled air to wine rooms
through ducts and can be located up to 25 ft away to reduce noise.
The dimensions and capacities are specified as follows:
EVAP UNIT
MODEL
L"xW"xH"-S"
WM-25SFCH
VINO-
22.5x15.875
2500SSH
x14.375-11
WM-45SFCH
VINO-
25.125x22.875
4500SSH
x16.375-18
WM-65SFCH
VINO-
25.125x22.875
6500SSH
x20.375-18
WM-85SFCH
VINO-
27.125x22.875
8500SSH
x22.375-18
NOTE:
CAPACITY IS DETERMINED UNDER THE CELLAR TEMPERATURE, THE
CELLAR AMBIENT TEMPERATURE AND THE CONDENSING UNIT AMBIENT
TEMPERATURE OF 55
EXTERIOR INSULATIONS. ANY LOWER CELLAR AND HIGHER AMBIENT
TEMPERATURES AND LOWER INSULATIONS WILL CAUSE REDUCING
CAPACITY AND THE CELLAR TEMPERATURE MAY NOT BE MAINTAINED
°
AT 55
F.
CAUTION:
LOW AMBIENT TEMPERATURE KIT IS REQUIRED IF THE INSTALLATION
AREA WILL BE BELOW 50
CAUTION:
LIQUID AND SUCTION LINES MAY DIFFER FROM WHAT ARE SHOWN
HERE, PLEASE CHECK ON THE UNITS FOR PROPER INSTALLATION.
Features and Specifications
Btu/h, CFM
COND UNIT
°
L"xD"xH"
(55/90
F)
WM-
250SCU
2500/220
18x12 x14
WM-
450SCU
4500/380
18x12 x14
WM-
650SCU
6500/490
24x18 x17
WM-
850SCU
8500/750
24x18 x17
°
°
F, 75
F AND 90
°
F.
°
F for a properly insulated wine
CAPACITY
REFRIGERANT
°
(55/75
F)
250 cu ft
R134a
1000 cu ft
R134a
1500 cu ft
R134a
2000 cu ft
R134a
°
F, WITH R11 INTERIOR AND R19
- 3 -
ELECTRICAL
WEIGHT(lb)
EVAP UNIT/
EVAP UNIT/
COND UNIT
COND UNIT
115V-60HZ-0.8A /
30/40
115V-60HZ-5.7A
115V-60HZ-1.8A /
39/60
115V-60HZ-6.9A
115V-60HZ-1.8A /
48/90
115V-60HZ-12A
115V-60HZ-2.1A /
58/115
115V-60HZ-15A