Vinotemp WINE-MATE VINO2500SSH Installation & Operation Manual

Vinotemp WINE-MATE VINO2500SSH Installation & Operation Manual

Split system
Hide thumbs Also See for WINE-MATE VINO2500SSH:

Advertisement

WINE-MATE Split System
Installation, Operation & Care Manual
VINO2500SSH 4500SSH
VINO6500SSH 8500SSH
V
i
n
o
t
e
V
i
n
o
t
e
READ AND SAVE THESE INSTRUCTIONS
w
w
w
.
w
i
n
e
m
a
t
e
.
c
w
w
w
.
w
i
n
e
m
a
t
e
.
c
m
p
I
n
t
e
r
n
a
t
i
o
m
p
I
n
t
e
r
n
a
t
i
o
w
w
w
.
v
i
n
o
t
e
m
p
.
c
o
w
w
w
.
v
i
n
o
t
e
m
p
.
c
o
m
o
m
n
a
l
C
o
r
p
.
n
a
l
C
o
r
p
.
m
o
m

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WINE-MATE VINO2500SSH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vinotemp WINE-MATE VINO2500SSH

  • Page 1 WINE-MATE Split System Installation, Operation & Care Manual VINO2500SSH 4500SSH VINO6500SSH 8500SSH READ AND SAVE THESE INSTRUCTIONS...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safety Information…...2 Features & Specifications.…………………….……………..3 Cellar Construction.…………………………….……………..7 Installer’s Instruction…………….…..….……..……………..8 Electrical Wiring…..…………….…..….……..……………..16 Temperature Control & Humidity Adjustment.………….22 Care Guide…………………………………………………….25 User’ Troubleshooting…….………………………………...26 Customer Support……………………………………………29 Warranty……………………………………………………….30 - 1 -...
  • Page 3: Important Safety Information

    Important Safety Information WARNING: • DO NOT USE A GROUND FAULT INTERRUPTER (GFI). • A DEDICATED 20 OR 30 AMP CIRCUIT IS REQUIRED (2500-4500SSH OR 6500-8500SSH). - 2 -...
  • Page 4: Features & Specifications

    • Wine-Mate split cooling systems VINO2500-8500SSH are designed and used to provide a cold temperature between 50~65 room at a normal environment. • The wine room will maintain humidity of 50~70% RH even when the environment becomes dry and humid. These temperatures and humilities are optimized for long term storage of wine.
  • Page 5 NOTE: LEAVE MINIMUM 3” CLEARANCE FOR ELECTRICAL WIRING AND REFRIGERATION PIPING. Parts included: Condensing Unit (discharge and suction valves installed) + Liquid Filter + Liquid Indicator Evaporator Unit (liquid line solenoid valve and expansion valve installed) Temperature Controller + Air Sensor Fig.
  • Page 6 Fig. 2 WM250-450SCU Condensing Unit Fig. 3 WM650-850SCU Condensing Unit - 5 -...
  • Page 7 Fig. 4 Liquid Filter Fig. 5 Liquid Indicator - 6 -...
  • Page 8: Cellar Construction

    Cellar Construction This is only a guide and shall be considered as minimum requirements. All interior walls and floors shall have a vapor barrier and a minimum of R11 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
  • Page 9: Installer's Instruction

    WINE-MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed, evacuated, charged and tested the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer.
  • Page 10 1. Condensing Unit • Place the condensing units WM250-850SCU in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly. • Condensing unit shall be elevated to avoid possible flooding and shaded from direct sun.
  • Page 11 1 - Process & Manometer; 2 – Receiver Discharge or Compressor Suction 3 – Liquid Line or Suction Line; 4 - Pressure Control 3. Evaporator Unit • The WM25-85SFCH evaporator units can be installed outside a wine room. • Supply air flow shall be unobstructed for at least 12” for free installation or 2”...
  • Page 12 valve, expansion valve, and suction line connection), returning to insulated suction line, suction valve and then back to condensing unit. 2) Use inverted siphons to prevent liquid from flooding back to the compressor and aid oil returning to the compressor. 3) Both discharge and suction valves must be in the middle positions during evacuating and charging.
  • Page 13 12) If the superheat is low, then decrease the evaporator suction pressure by turning the hex nut (5/16”) counter-clockwise. 13) Both discharge and suction valves must be in the back positions before disconnecting evacuating and pressure gauges. The line sizes and refrigerant charges are listed as follows. REFRIGERATION MODEL LINES...
  • Page 14 A. P70 Single/Dual Control Fig. 11 Adjustable Pressure Control B. PS2 Dual Control Fig. 12 Adjustable Pressure Control - 13 -...
  • Page 15 Use of the encapsulated pressure control (if applicable) Fixed suction pressure setting: Cut in = 32 psig; Cut out = 10 psig Fig. 13 Fixed Pressure Control Use of the condenser fan control (if applicable for low ambient kit) Head pressure setting: Cut in=170 psig; Cut out=120 psig; Differential=50 psig It closes on rise of pressure.
  • Page 16 High superheat and high subcooling Low suction pressure and low head pressure Normal to high superheat and low subcooling Low suction pressure and low head pressure Low superheat and low subcooling k. Low suction pressure and low to normal head pressure High superheat and normal to high subcooling Low suction pressure and normal head pressure High superheat and normal subcooling...
  • Page 17: Electrical Wiring

    CAUTION: • HIDDEN LINES ARE FOR FIELD WIRINGS. • MINIMUM 14 GAUGE WIRES FOR POWER LINES. • IF EQUIPPED WITH LOW AMBIENT CONDITION KIT, USE LOW AMBIENT TEMPERATURE WIRING DIAGRAMS. BEFORE POWER THE CONDENSING UNIT. ONLY TURN ON THE COMPRESSOR AFTER THE CONDENSING UNIT HAS BEEN POWERED FOR 24 HOURS.
  • Page 18 Fig. 15 VINO6500SSH Electrical Wiring Diagram - 17 -...
  • Page 19 Fig. 16 VINO8500SSH Wiring Diagram - 18 -...
  • Page 20 Fig. 17 Low Ambient Temperature VINO2500 & 4500SSH Wiring Diagram - 19 -...
  • Page 21 Fig. 18 Low Ambient Temperature VINO6500SSH Electrical Wiring Diagram - 20 -...
  • Page 22 Fig. 19 Low Ambient Temperature VINO8500SSH Wiring Diagram - 21 -...
  • Page 23: Temperature Control & Humidity Adjustment

    Temperature Control & Humidity Adjustment 1. Temperature Setting • Set the temperature at 55 • On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature. • Allow 24 hours to stabilize the temperature for each new temperature setting operation 1.
  • Page 24 2.1 LED Functions MODE Flashing Flashing Flashing 3) Alarm Signals 3.1 Code Description MESSAGE CAUSE Temperature probe faulty High temperature alarm Low temperature alarm External alarm 3.2 Alarm Recovery Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe restarts normal operation.
  • Page 25 5) Parameter Programming 1. Press the SET + keys for 3 sec until the “°C” or “°F” LED starts blinking, then release the keys. 2. Press again the SET + displayed, then release the keys. The first parameter Hy will be displayed. 3.
  • Page 26: Care Guide

    In general, always unplug system or disconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an extended attachment to clean the coil when it is dusty or dirty.
  • Page 27: User' Troubleshooting

    User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive Complaint Possible Causes a. No power 1.Unit not b. Power cord unplugged running c. Setting higher than ambient temperature d.
  • Page 28 running continually e. Malfunctioning fans Improper condenser airflow g. Dirty Condenser h. Iced evaporator Sealed system problem Undercharge or overcharge a. Improper room insulation & seal 6.Unit running too long b. Exhaust restricted c. Room too large d. Ambient temperature extremely high e.
  • Page 29 10.Noisy a. Mounting area not firm b. Loose parts operation c. Compressor overloaded due to high ambient temperatures or airflow restriction d. Malfunctioning components a. Add support to improve installation b. Check fans, cabinet washers, tubing contact and loose screws. c.
  • Page 30: Customer Support

    Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.com - 29 -...
  • Page 31: Warranty

    BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
  • Page 32 VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.

Table of Contents