TROUBLE SHOOTING
Problem
Solution
UV Warning Troubleshooting:
WARNING! UV Eye hazard.
The UV 1, 2 or 3
lightning bolt or
Wear UV-absorbing sunglasses if available. Do Not look into the tank any longer
UV WARNING in-
than necessary to determine if the bulb is operating. This can be done without
dicator blinks and
looking at the bulb itself.
you hear 3 long
beeps.
Prolonged direct eye exposure to ultra-violet light may cause serious eye dam-
age.
If UV 1 or 3 is blinking, you will need to make the bulb viewable by referring to the
steps on Pgs 24 and 26. Check the electrical wire to make sure it is plugged in.
To test, restart the machine. If either bulb does not illuminate on start up, it will
need to be replaced.
If UV 2 is blinking, you will need to make the bulb viewable by referring to the
steps on Pg 25. Check the electrical wire to make sure it is plugged in. To test,
dispense some water into a glass. If it does not illuminate during that process, it
will need to be replaced.
Power Cord Troubleshooting:
Check the circuit breaker in the facility and test with another device to assure the
The
Appliance
does
not
work
outlet is live. Check to ensure the voltage being delivered to the outlet is in the
even
after
the
correct operating range for the device. Make certain that the plug connection to
power
cord
is
the wall outlet is tight and secure and the cable is not damaged
plugged in.
Display Troubleshooting:
To Reset:
The system de-
tected water leak-
• Power the machine off, and unplug the power cord.
age on the base.
The red warning
• Locate overflow cup (Figure 1), slide off and allow the water to drain.
light indicator is
• Place theoverflow cup back in place.
lit on the screen
accompanied by
• Power the machine back on.
the booster pump,
If Cause of Leak is Unknown:
water production,
cooling and other
• Power off the machine.
function fault.
• Remove overflow cup during testing.
• Fill the bottom tank with water and turn on machine.
• While water is pumping, inspect the front filters for leaks.
• Power off the machine and check the tubing on the bottom tank for leaks.
• Make sure the drainage tubing in the back is tight and secure.
• Make sure the water collector is in the correct position.
• Turn the Appliance back on.