How the Atmospheric Water Generator Works ............. 7 Key features of the Atmospheric Water Generator ............8 Components of the Atmospheric Water Generator ............8 Display Description – Model 30 Series ............... 11 Additional Display Options and Settings ..............12 SET-UP ..........................14 Preparation and Location ....................14...
Page 3
....................39 MAINTENANCE LOG ......................40 NOTICE: The EcoloBlue Life & Energy Atmospheric Water Generator 30 Series is intended for INDOOR USE ONLY in homes or small office. 3109 Grand Avenue - Suite 423, Miami, Florida 33133 5702 Marsh Drive -Unit K, Pacheco, California 94553 800-691-6043 Outside U.S.
Generator is a state-of-the-art water generating Appliance using the latest technology available to the industry. EcoloBlue designed your Atmospheric Water Generator with one objective in mind: produce the maximum amount of high quality drinking water using only a minimum amount of electricity. In addition to atmospheric water production, the Appliance can also be used as a conventional water purifier by connecting it to an external municipal (city) water source.
Do not, under any circumstances, cut, remove, or bypass the grounding prong. WARNING! Your EcoloBlue must be plugged directly into a properly grounded and polarized three-prong receptacle. lf the wall receptacle you intend to use will not accept a three-prong plug, or if you are not sure the outlet is...
Page 6
Always use the correct replacement and maintenance parts specified by the manufacturer. Failure to do so may void the warranty. EcoloBlue 30s ONLY CO2 Canisters. Contents under high pressure. Handle with care! Do not drop the cylinder, throw it, or carry it in a way that it may strike objects or surfaces while being carried.
EcoloBlue Life & Energy Atmospheric Water Generator, Model 30 Series. This warranty gives you specific legal rights; you may also have other rights, which vary from state to state or province to province.
The ultraviolet lamps help to sanitize and prevent growth of bacteria and other microorganisms in the system. The UV sanitization process is automatically controlled by the microprocessor. Multi-Stage Filtration System EcoloBlue’s high-quality, great tasting water is the result of our unique multi-stage filtration system. Air Filtration Prevents micro-particles and dust from entering the Appliance.
Refer to Figures 1 and 2 for more information. Novel and Attractive Cabinet Style The EcoloBlue Atmospheric Water Generator has a smaller and sleeker design compared to other Gen- erators on the market. The unit is more compact and more versatile.
Page 10
1 Motherboard 2 Exhaust 3 Air Filter 4 Collection Tray Mineral 5 Collection Tank 6 Air Filter 7 Hot Water Drain 8 RO Water Drain 9 Water Inlet 10 Overflow Cup Figure 1 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
12.Setting Button – In the Mode Menu, use Set to change the selected option. Also used as a +/increase button in selected settings. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
10. FD***: displays filter use. Press SET button to reset filter counter. 11. C/F-C: Temperature in Celcius. C/F-F: Temperature in Fahrenheit. This option is located after all of the Temperature options. 12. RESET: Press SET button to reset to factory settings. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Page 14
Press and hold to start up or shut down the Appliance. Press and hold LOCK button after beep Press and hold HOT button to dispense hot water. Press and hold COLD button to dispense the cold water. (18) www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
SET-UP Setting up the EcoloBlue Atmospheric Water Generator involves proper Preparation and Location; RO Filter Installation; Cleaning; and Flushing the System prior to use. Setup usually requires approximately 2 hours to complete. The wrench, tubing coil, and pipe tape supplied with the Generator are for optional connection to a municipal water supply.
Confirm all the parts are there (Refer to Figures 1 and 2) Place the unit in desired location Lock brake levers Install Reverse Osmosis Filter Clean the bottom storage tank Flush the system Connect to Municipal (City) Water (optional) www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Close the front panel Figure 3 Figure 4 Open the bottom front panel. Gently pull filter cap towards you. Figure 5 Figure 6 Remove RO filter from packaging. Push RO filter up into cap. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
When draining complete, replace plug and cap. Turn the power ON and the Appliance will now begin generating water. Maximum generation may take up to 72 hours. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Appliance. Turn the power OFF (Figure 12). Drain out all remaining water from the rear HOT Water Drain outlet. Secure water tube hand tight. Turn ON the water supply and check for leaks. Tighten fittings as necessary. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Only when the water in the Appliance reaches a proper level (three bars on the allotment tank icon) will the heating/cooling mechanism be triggered. (Generally, the first heating/cooling will start within 24-72 hours during the first operation, depending on local temperature and humidity conditions.) www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
If the Appliance was not in use for more than 7 days or it has been in continuous operation for 6 months, it is time to run a sanitizing cycle. Please follow the steps in SANITIZING to sanitize the system. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Lower filter into place. (Figure 19) Repeat for EF2, Mineral, EF3 Please note: TheReverse Osmosis Filter is changed every 2 years or as needed. After replacing filters, flush system with 1 Gallon(3 Liters) of water by adding to collection tank. (See Page 17) www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Page 24
Each filter is changed in the same manner. Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Wait for 10 minutes to allow the UV to cool down. Remove the screws at the back of the top cover and put them in a secure location. Remove the cover (Figure 22 and 23, page 20). www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Page 26
20). Figure 24 Figure 25 Figure 26 Figure 27 Please NOTE: For 1st Time UV Bulb replacement it is necessary to cut the seal to separate the top of the Styrofoam container. Figure 28 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Pull gently on wires to release silicone plug and remove the UV bulb (Figure 32). Replace with new bulb. Plug in the Appliance and turn the power ON. ( Figure 13, page 20). Figure 29 Figure 30 Figure 31 Figure 32 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Cleaning the Air Filter The EcoloBlue Appliance contains three air filters as pictured below in figures 39 and 40. We assigned the air filters in the figures with the letters A, B, and C to guide you on the cleaning instructions. Air filters A and C follow the same cleaning instructions and air filter B has a different set.
Page 29
Straighten and replace the filter into its holder in the Generator. Plug in the Appliance and turn the power ON. (Figure 13, page 20). Figure 38 Figure 39 Figure 40 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Rinse the bottom tank with water and wipe dry. Make sure to wipe off the funnel filter during this process. Thoroughly wipe off any dirt/dust on tank walls. Reassemble (Figure 47) Plug in the Appliance and turn the power ON ( Figure 13, page 20). Figure 41 Figure 42 www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Switch the power OFF and unplug Appliance. Drain all remaining water from hot water drain outlet in the back (Figure 53). Plug in the Appliance, replace nozzle and turn the power ON to begin water generation. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Page 33
Add water to fill bottom tank. DO NOT turn machine on. Let soak for 2 hours. Drain solution, rinse with tap water and wipe out tank. Plug in the Appliance and turn the power ON to begin water generation. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
4. Press and release right side door. 5. Align the EcoloBlue bottle with charging port, and screw tightly (CLOCKWISE) (Figure 7 & 8) 6. Inject with CO2: Press the soda button for 1-3 seconds, repeat to increase carbonation (Figure 10).
• Power off the machine and check the tubing on the bottom tank for leaks. • Make sure the drainage tubing in the back is tight and secure. • Make sure the water collector is in the correct position. • Turn the Appliance back on. www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...
Page 37
After approximately 6 months time of operation, the filters may be clogging. If so, “REPLACE” on they must be replaced. Replace with a new EcoloBlue filter by following the steps display is illumi- in MAINTENANCE. Reset the filtration warning time by following Step 10 on page nated or blinking.
CERAMIC MINERAL FILTER The EcoloBlue 30 Series Ceramic Mineral Filter is composed of functional minerals that not only help increase the pH in the water to a consistent level, but also improves the water taste by releasing healthy minerals such as calcium and magnesium.
Page 39
Note: EcoloBlue reserves the right to make changes/amendments/deletions/revisions and/or varia- tions in and to EcoloBlue Atmospheric Water Generator and in and to the contents of this manual at any time and without prior notice to those who have purchased earlier versions of any EcoloBlue Model or who have received earlier issued versions of this Manual.
Page 42
8 Xihua Road, Wuxi, 8 Xihua Road, Wuxi, New Wuxi District New Wuxi District Jiangsu Province Jiangsu Province P.R. China 214028 P.R. China 214028 T: +86 133 2810 5912 Designed by EcoloBlue in California Assembled in China www. EcoloBlue.com | 800-691-6043 | 1-925-231-0206...