Management Options - D-Link DGS-1216T Getting Started Manual

For web smart switch
Hide thumbs Also See for DGS-1216T:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Management Options

The D-Link Web Smart Switch can be managed through
any port on the device by using the Web-based
Management Utility or through any PC using the
SmartConsole Utility.
If you want to manage only one D-Link Web Smart
Switch, the Web-Based Management Utility is the better
option. Each switch must be assigned its own IP Address,
which is used for communication with Web-Based
Management Utility or an SNMP network manager and
the PC should have an IP address in the same range as
the switch.
However, if you want to manage multiple D-Link Web
Smart Switches, the SmartConsole Utility is the better
option. Using the SmartConsole Utility, you don't need
to change the IP address of your PC and it is easy to
start the initial setting of multiple Smart Switches.
Please refer to the following detailed installation
instructions for the Web-Based Management Utility and
the SmartConsole Utility.
Web-based Management Utility
After a successful physical installation, you can configure
the switch, monitor the LED panel, and display statistics
graphically using a web browser, such as Netscape
Navigator (version 6.2 and higher) or Microsoft
Explorer (version 5.0 and higher).
You need the following equipment to begin the web
configuration of your device:
A PC with a RJ-45 Ethernet connection
A standard Ethernet cable
Step 1
Connect the Ethernet cable to any of the ports on the
front panel of the switch and to the Ethernet port on the
PC.
Figure 6. Connected Ethernet cable
Step 2
In order to login and configure the switch via an Ethernet
connection, the PC must have an IP address in the same
range as the switch. For example, if the switch has an IP
address of 192.168.0.1, the PC should have an IP
address of 192.168.0.x (where x is a number between 2
and 254), and a subnet mask of 255.255.255.0.
Open your web browser and enter http://192.168.0.1
(the factory-default IP address) in the address box. Then
press <Enter>.
Figure 7. Enter the IP address 192.168.0.1 in the web
The web configuration can also be accessed through the
SmartConsole Utility. Open the SmartConsole Utility
and double-click the switch as it appears in the Device
List. This will automatically load the web configuration in
your web browser.
®
Internet
Step 3
When the following logon box appears, enter "admin" for
the password. Press OK to enter the main configuration
window.
Step 4
Before entering the Web-based Management Utility,
the Smart Wizard will guide you to quickly configure
some functions, such as Password Settings, SNMP
Settings, and System Settings. If you don't plan to
change anything, click Exit to exit the Wizard and enter
the Web-based Management Utility. For a detailed look
3
browser
NOTE: The switch's factory
default IP address is 192.168.0.1
with a subnet mask of 255.0.0.0
and a default gateway of 0.0.0.0.
Figure 8. User authentication window

Advertisement

Table of Contents
loading

Table of Contents