  • Page 1 Ambient Noise Sensor Model ANS501 Installation and Use Manual © 2003 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice. 54-2096-01A Printed in Korea. 0312...
  • Page 2 Every effort was made to ensure that the information in this guide was complete and accurate at the time of printing. However, information is subject to change. Important Safety Information WARNING: To Reduce The Risk of Fire Or Electric Shock, Do Not Expose This Apparatus To Rain Or Moisture.
  • Page 3: Table Of Contents

    Contents DESCRIPTION ...4 Package Contents ...4 Features...4 PANEL DESCRIPTIONS ...5 SENSOR MICROPHONE CONNECTIONS ...6 Sensor Microphone Wiring ...6 Wiring Multiple Microphones ...6 OPERATION ...7-8 Front Panel Controls ...7 AUX Level Control ...7 Relative Gain Control ...7 Ramp Speed Control...7 Maximum Boost Control ...7 Threshold Controls ...7 Front Panel Switches and Indicators ...7 Mode Switch ...7...
  • Page 4: Description

    Description The Bogen Model ANS501 Ambient Noise Sensor is designed to electronically adjust the level of a page announcement or background music in an area of a building where ambient noise levels are continuously changing. It ensures that page announcements or background music are intelligible even during periods of high ambient noise levels.
  • Page 5: Panel Descriptions

    4. Balanced Input - High-impedance electronically balanced input (pluggable screw terminal). 5. Sensor MIC Input - Input connections for ANS500M sensor microphone(s) (pluggable screw terminal). 6. Defeat Input - The effects of the ANS501 will be defeated when these terminals are shorted together (plug- gable screw terminal).
  • Page 6: Sensor Microphone Connections

    Wiring Multiple Microphones Physical connections can be made using either Home Runs back to the ANS501 from each sensor mic or by daisy- chaining sensor mics, depending on the installation.The maximum total wire length from any sensor mic to the ANS501 must be kept below 2000 ft.
  • Page 7: Operation

    Threshold Controls Activity threshold is set just above typical operating level of the program material applied to the gain processing stage of the ANS501.Ambient threshold adjusts the ambient noise input threshold from 64 dBspl to 112 dBspl. Front Panel Switches and Indicators Mode Switch The Mode switch can be set to “Run”...
  • Page 8: Connections

    Low-impedance unbalanced RCA output. Signal gain responds to ambient noise changes. AUX Input Mono summing, stereo, unbalanced RCA inputs. This input bypasses the gain adjustment process of ANS501 and is fed directly to the output, via the AUX level control.
  • Page 9: Module Setup

    It is often undesirable to have the background music level increase as ambient noise increases since it only adds to the overall noise in the area.The ANS501 provides an Aux input that bypasses the gain adjustment process so that it does not change with ambient noise levels.
  • Page 10: Normal Mode

    Module Setup, cont. Normal Mode All sources are affected by the gain adjustment process. Background music source will need to be routed through the main mixer inputs, which will be affected by the gain adjustment process. Refer to page 12 for illustration. Start with all POTS turned fully clockwise (AUX IN is not used in this mode).
  • Page 11: Bypass Mode Illustration

    Module Setup, cont.
  • Page 12: Normal Mode Illustration

    Module Setup, cont.
  • Page 13: Ambient Level Settings

    Ambient Level Settings Use this table to estimate the general dBspl level of the area’s ambient noise if actual measurements are not available. Specifications Gain (Boost): Frequency Response: S/N (20 Hz - 20 kHz): Input Impedance: Output Impedance: Gain Ramp Speed: Typical Ambient Noise Level Very High Noise 85-95 dB...
  • Page 14: Block Diagram

    Block Diagram...
  • Page 15: Limited Warranty

    Limited Warranty The ANS501 is warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser.Any part of the product covered by this warranty that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA.The product will be returned to you freight prepaid.This warranty does not extend to any...
  • Page 16 50 Spring Street, Ramsey, NJ 07446, U.S.A. Tel. 201-934-8500, Fax: 201-934-9832, www.bogen.com...