Options And Accessories - Hatco HDW Series Installation And Operating Manual

Table of Contents

Advertisement

English
Digital Temperature Controller
The digital temperature controller is factory installed and takes
the place of the standard drawer warmer control panel. Use
the following procedure to operate the digital temperature
controller.
Startup
1. Move the Power I/O (on/off) switch(es) to the I (on) position.
• The corresponding digital temperature controller will
energize and the current temperature of the drawer or
"LO" will appear on the TEMPERATURE display. "LO"
indicates the drawer temperature is below 21°C (70°F).
2. Press the
key three times to verify the setpoint
temperature. ("SP" will be displayed after the second
press.) See the RECOMMENDED SETTINGS chart on
the control panel or the FOOD HOLDING GUIDE in this
manual.
• The setpoint temperature will be shown for 10 seconds.
After 10 seconds, the TEMPERATURE display will revert
to the current temperature of the unit. To change the
setpoint temperature, refer to "Changing the Setpoint
Temperature" in this section.
NOTE: The digital temperature controller is pre-set to a setpoint
temperature of 85°C (185°F) at the factory. Once the
setpoint temperature is changed, the new setpoint
temperature will remain in memory until it is changed
again. The minimum to maximum setpoint temperature
range is 21°C (70°F) to 93°C (200°F).
CAUTION
BURN HAZARD:
• Some exterior surfaces on unit will get hot. Use caution
when touching these areas.
• Use caution when opening drawer. Hot air escapes
when drawer is open.
3. Allow unit 15–20 minutes to reach operating temperature.
Shutdown
1. Move the Power I/O (on/off) switch to the O (off) position.
The digital temperature controller and heated drawer will
shut off.
Changing the Setpoint Temperature
Use the following procedure to change the setpoint temperature.
1. Press the
key three times. The current setpoint
temperature will be shown on the TEMPERATURE display
("SP" will be displayed after the second press).
2. Press the
key or
the setpoint temperature.
3. Press the
key to lock in the new setpoint temperature.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
Form No. HDWM_CN-0817
key within 10 seconds to change

OPTIONS AND ACCESSORIES

Changing Fahrenheit and Celsius Setting
Use the following procedure to change between Fahrenheit
and Celsius on the display.
1. Press the
key once. Either an "F" for Fahrenheit or "C"
for Celsius will be displayed.
2. Press the
key or
between "F" (Fahrenheit) and "C" (Celsius).
3. Press the
key three times to lock in the new setting.
The TEMPERATURE display will go blank for two seconds
to show that the new setting has been accepted.
NOTE: After 10 seconds of inactivity during the programming
process, the controller will exit programming mode
automatically without saving any changes.
Control Panel with Digital Temperature Controler
15
key within 10 seconds to change
Digital
Temperature
Controller
RECOMMENDED
SETTINGS Chart
POWER I/O
(on/off)
Switch

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents