Scope of delivery 1 x CAI21x0 (top shell, bottom shell or tabletop device) 2 x release bracket 4 x Phillips head screw 4 x dowel assembly instruction Product information instruction manual Safety instructions General safety regulations Attention! Assembly, installation, commissioning and repair of electronic devices must be carried out by qualified electricians and in compliance with the current standards.
Technical data supply voltage: +24 V ± 8 % (power supply and control unit) housing: aluminium anodised (colors as listed in price list) dimensions CAI1100 H 163 mm x W 192 mm x D 16 mm dimensions CAI1100: H 156 mm x W 192 mm x D 150 mm weight: 936 g (CAI2100), 1473 g (CAI2110) acceptable ambient temperature:...
Indication and operating elements Term Function call acceptance, activate speaking, speech button simplex communication end communication ring tone selection (door call front-door station 2 AS > AS- border*) door release (factory setting) door release but- end communication ...
Intended use The CAI21x0 are video indoor stations with color screen for hands-free talking. Manual- ly controlled simplex communication can be activated. The CAI21x0 are suitable for surface-mount and can be used as tabletop device. They can be used for the operation within TCS audio systems and combined audio / video systems.
(limited by other indoor or front-door stations, to which a voice connection is estab- lished) audio privacy function and automatic call cut-off Videounit video surveillance: image button to activate the image resp. to switch between different cameras AS-dependent video image activation ...
Connect the lines 0.08 … 0.82 mm (Ø 0.32 … 1.0 mm) acceptable cross-section (diameter) max. number of wires per terminal contact each 2 x 0.8 mm, 3 x 0.6 mm Further wires have to be connected via auxiliar terminals! ...
Deinstall the device For deinstalling the device, the enclosed release bracket is necessary. Insert the release bracket into the opening of the bottom shell behind the device (1). Push the device upwards (2) and pull it out towards you (3).
Put up the table rack Turn the table rack into the desired position and fix the position by tightening the knurled screws by hand. The cable is already pre-installed. max. 60° Cable assignment Wires Connect to Plug PIN no. connection terminal: orange-green green-white...
Deinstall the device Loosen the grub screw for dein- stalling the device. Take the de- vice into both hands. Push the device upwards (3) and pull it out towards you (4). Lock pins 4 x: Wiring diagram Attention! Observe max. number! (see Intended use, page 6)
Connection diagram Commissioning First install the system completely, than connect it to the mains voltage! Install the devices of the system completely. V1 and V2 must not be connected with the P-, a- or b-wire. When connecting the video wires V1 (+) and V2 (−) the polarity must be observed. ...
2d select internal call tone Press the function key as often as the required ring tone sounds. The ring tone selected last, will be stored. Press call OFF button short. In case that no button is pressed for around. 8 sec, the device ends the ring tone selection automatically.
Configuration options configo Function manually TCSK-01 as of version 1.7.x – – fixed simplex communication simplex communication to the front-door – – station – – ring tone volume ring tones for 2 front-door calls, internal – calls and floor calls call diversion door release automatic internal call via function key...
Page 15
Initiate the programming Press the call OFF-button (8 sec), release until an acknowledgement tone sounds shortly Pre-selection End-selection Press the button (8 sec) until an acknowl- shortly press the button, edgement tone sounds shortly and the green an acknowledgement tone sounds Programming func- LED blinks, release the button shortly and the green LED expires...
Page 16
Programming func- Pre-selection End-selection tion internal call Execute at the required indoor station: (at function key) press speech button control function 8 (on function key) automatic hands-free talking after internal call switch on (when switched off) or switch off (when switched on) switch on floor door release function (if...
Page 17
Programming func- Pre-selection End-selection tion block ring tone selec- tion block extended pro- gramming deactivate program- ming lock Attention! Switch on the pro- gramming mode of the system at the BVS first. Execute the steps 1 to 4. ...
Programming the function key of the basic unit with Service Device TCSK-01 door release automatic call diversion internal call 1 control function 8 parallel allocation activate parallel call switch off NOTE: To deactivate parallel allocation means parallel allocation to serial number 0. ser.
Error pattern Possible cause Our suggested solution The video image is black and The color saturation control of the Adjust the contrast or color satura- white. indoor station is set to a minimum. tion control. The transmission level of the vid- At many components of the video eo BUS is too low.
Page 21
In one building block with multi- Image interferences due to transi- The P-wire is not connected correct- ple indoor stations, only one tion resistance. indoor station shows black lines The connection contacts are not on the video image. completely fixed. Image interferences due to near Relocate the video distributor or any disturbing sources such as exter-...
Page 22
Contours of a second image are Two video sources interfere. Please remove the second video visible. source from the strand. Connect the second video source, if necessary, via a video switch to the existing TCS:BUS. No image. When pressing the No signal present.
Repair Repairs have to be carried out only by qualified electricians. Cleaning Avoid water from entering the device! Do not use any abrasive detergents! Clean the indoor station with a dry or slightly wet cloth. Remove stronger stains with a pH- neutral cleaner.
Need help?
Do you have a question about the Adapto CAI2100 and is the answer not in the manual?