Pfeuffer HFM Operating Instructions Manual

Hay and straw moisture meter

Advertisement

Quick Links

Artikelnummer Betriebsanleitung:
1315 0051
Article number operating instructions:
Operating instructions
for the hay and straw moisture meter
HFM
Pfeuffer GmbH
Flugplatzstraße 70
97318 Kitzingen
GERMANY
Phone: +49 9321 9369-0
Fax:
+49 9321 9369-50
info@pfeuffer.com
Revision 5/12.02.2020
www.pfeuffer.com
Translation of the original operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HFM and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pfeuffer HFM

  • Page 1 Artikelnummer Betriebsanleitung: 1315 0051 Article number operating instructions: Operating instructions for the hay and straw moisture meter Pfeuffer GmbH Flugplatzstraße 70 97318 Kitzingen GERMANY Phone: +49 9321 9369-0 Fax: +49 9321 9369-50 info@pfeuffer.com Revision 5/12.02.2020 www.pfeuffer.com Translation of the original operating instructions...
  • Page 2: Table Of Contents

    Wrong measurement values ..................8 10.3 Damages on the device ....................8 Warranty ..............................8 Disposal ..............................8 Imprint ..............................8 Declaration of Conformity ........................9 2 | 10 Operating instructions hay and straw moisture meter HFM | Revision 5...
  • Page 3: Introduction

    Safety Safety instructions for the buyer IMPORTANT! Make sure that each person who works for the first time with the Pfeuffer HFM has read and understood this manual. DANGER! Make sure that the Pfeuffer HFM is kept in a place that is not accessible to unauthorized persons.
  • Page 4: Personal Protective Equipment

    During the handling of the device there may be a risk of injuries because of the pointed measuring lance tip. WARNING! The Pfeuffer HFM must not be operated in the area of live parts and wiring. There is a risk of electric shock! WARNING! The Pfeuffer HFM must not be operated in explosive areas.
  • Page 5: Working With The Device

    [Moisture] or [Temperature] keys. If there is no measurement above 12 % moisture for a period of 10 seconds and no key is pressed, the display lighting is switched off. Revision 5 | Operating instructions hay and straw moisture meter HFM 5 | 10...
  • Page 6: Freezing Of Displayed Values (Hold Function)

    To display the battery voltage, briefly press the button [Off]. The battery voltage in Volts appears on the display for about 3 seconds. The unit automatically switches back to the current display mode. 6 | 10 Operating instructions hay and straw moisture meter HFM | Revision 5...
  • Page 7: Acoustic Warning

    The calibration of Pfeuffer HFM is designed for an average bale density. In bales with higher density a higher moisture level will tend to appear and at lower density bales a lower value will be displayed. This fact is advantageous in practice in many cases, because, with higher density bales increased sensitivity is advised with respect to quality and storability.
  • Page 8: Troubleshooting

     Warranty Over and above statutory warranty for Pfeuffer HFM probe following warranty provisions apply: The Pfeuffer GmbH guarantees the function and repairs or replaces all the parts that have a material or  manufacturing damage within the warranty period.
  • Page 9: Declaration Of Conformity

    EN 61000-6-3:2007 + A1:2011 EN 61326-2-3:2006 This explanation is given by the manufacturer Pfeuffer GmbH Flugplatzstraße 70 97318 Kitzingen GERMANY Submitted by: Kitzingen, ___________________________ ___________________________________ Lothar Pfeuffer, General Manager Revision 5 | Operating instructions hay and straw moisture meter HFM 9 | 10...
  • Page 10 Notes Revision 5 | Operating instructions hay and straw moisture meter HFM 10 | 10...

Table of Contents