Artikelnummer / Article no. 1336 0821
Installation and
Operating instructions
Pfeuffer GmbH
Flugplatzstraße 70
97318 Kitzingen
GERMANY
Phone:
+49 9321 9369–0
Fax:
+49 9321 9369–50
Email:
info@pfeuffer.com
Internet: http://www.pfeuffer.com
Translation of the original operating instructions
Revision 3/10.07.2017

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GTM 800 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pfeuffer GTM 800

  • Page 1 Artikelnummer / Article no. 1336 0821 Installation and Operating instructions Pfeuffer GmbH Flugplatzstraße 70 97318 Kitzingen GERMANY Phone: +49 9321 9369–0 Fax: +49 9321 9369–50 Email: info@pfeuffer.com Revision 3/10.07.2017 Internet: http://www.pfeuffer.com Translation of the original operating instructions...
  • Page 2 The Pfeuffer GmbH has prepared and reviewed these Operating Instructions with the greatest care. However, no guarantee is made for its completeness or accuracy. Subject to technical modifications.
  • Page 3: Table Of Contents

    Installation and operating instructions GTM 800 Table of contents Introduction ..........................4 General ............................4 Note – applied as directed ......................4 Safety ............................4 Symbol and note explanation ..................... 4 Operator safety instructions ...................... 5 Working with electric components .................... 5 protection area –...
  • Page 4: Introduction

    Internet. We would be happy to help you if you need further information! Note – applied as directed The GTM 800 system is designed exclusively for the temperature measurement in grain stores. Other applications are not allowed without permission of the manufacturer. These operating instructions draw your attention to very important details referred to the application of the measuring system.
  • Page 5: Operator Safety Instructions

    The operator is obliged to use the GTM 800 system only in perfect condition.  The operator of the GTM 800 system is responsible for the safety devices, that they are not changed, that they are working and that they are not blocked. It is not allowed to remove, make unusable or bridge over safety devices from the machine, such as locks, covers and housing switches.
  • Page 6: Instructions For Use In Explosion Protection Zone 22

    In addition, a lost battery is to be negatively evaluated for environmental reasons. 4. The GTM 800 may not remain permanently in the ex-zone. It is only carried for the purpose of measuring in the ex-zone, and then removed again.
  • Page 7: Packing, Transport

    Installation and operating instructions GTM 800 Packing, transport Transport and storage 3.1.1 Notices and protective measures for the transport  Use the supplied original packing for dispatch only  Treat with usual care  Keep instrument in original packing and prevent it from moisture ...
  • Page 8: Installation And Commissioning

    Assembly of the GTM800 Due to the portability of the GTM 800 device any location for the printer (option) can be chosen. Do not expose the printer to direct solar irradiation, heat, humidity and dust. Pay attention to a correct paper feed when using endless paper.
  • Page 9: Configuration

    Installation and operating instructions GTM 800 Configuration Survey of the single keys and indications Display with key assignment Keys Switch on Press the central key  Measure Indicate . . .SET . Menu Installation/Configuration   Select the menu item »Settings« by means of the arrow keys...
  • Page 10 Then enter the figure » 4 « by means of the arrow keys and confirm by means of the central key Code ? Code ?     .++. .NEXT. .--. .++. .NEXT. .--. © 2017 – Pfeuffer GmbH Seite 10 von 22 Revision 3...
  • Page 11: Configuration Probes

    Installation and operating instructions GTM 800   Then enter the figure » 3 « and confirm by pressing the central key Code ? Code ?     .++. .NEXT. .--. .++. .NEXT. .--. Now the menu »Installation and Configuration« appears.
  • Page 12: Reset

    If you have any questions, please contact Pfeuffer GmbH. Auto Off/Sec »Auto Off/Sec« regulates the period time the GTM 800 remains activated without entering any data.   This figure is indicated in seconds and can be changed by means of the arrow keys...
  • Page 13: Routine Operation

    No.+ .SET .Meas .SET . The GTM 800 indicates the measured readings on the display. To select the next probe, press the left key  again and then press the right key  to activate the measurement. Probe no. Probe no.
  • Page 14: Print Measurement

    . . .SET . .SET . .SET . The printing starts. Please hold up the connection between the IR module and the GTM 800 until the printing procedure is completed. © 2017 – Pfeuffer GmbH Seite 14 von 22 Revision 3...
  • Page 15: Other Settings

    Installation and operating instructions GTM 800 If the setting was changed to Excel format, this is indicated on the display: EXCEL-file Print Probe no. . . .SET . The correct reception of this format on the PC requires the configuration of the interface as well as the use of a terminal program! This format is not suitable for the output on the printer! If you have any questions, please contact Pfeuffer GmbH.
  • Page 16 The submenu »Reset time« deletes the date and time settings. After pressing the central key date and time settings must be readjusted. Time  Reset time <---- . . .SET . © 2017 – Pfeuffer GmbH Seite 16 von 22 Revision 3...
  • Page 17: Menu Limits

    Installation and operating instructions GTM 800 7.1.2 Menu Limits Allows the determination of the upper limit at which the alarm signal is to be raised. Select the menu item »Limits« by means of the arrow keys   and confirm it by pressing the central key...
  • Page 18: Menu Delete Data

    Allows the inquiry of the release. Activate this option by pressing the central key Language Version 1.00  Version GTM 800 11.11.04 <---- . . . . .SET . .SET . © 2017 – Pfeuffer GmbH Seite 18 von 22 Revision 3...
  • Page 19: Menu Display

    Installation and operating instructions GTM 800 Menu Display Allows the modification of the display settings (illumination, brightness, contrast). Confirm by pressing the central key Print/Output  Display  Light on/off Inst./Config. Brightness . . . . .SET . .SET ....
  • Page 20: Menu Contrast

    A battery change must always be carried out outside the ex-zone. The battery could be lost and pose a hazard. In addition, a lost battery is to be negatively evaluated for environmental reasons. © 2017 – Pfeuffer GmbH Seite 20 von 22 Revision 3...
  • Page 21: Technical Data

    Installation and operating instructions GTM 800 Technical data Specifications (please enter): Company / City: Pfeuffer order no. Designation: GTM 800 Serial no. Year of construction: Measuring device GTM 800 Measuring range -20°C to 70 °C Measuring accuracy ±0.5 °C Ambient temperature housing 5 °C to 40 °C...
  • Page 22: Declaration Of Conformity

    Any modification to the temperature monitoring system not agreed with us shall result in this declaration becoming null and void. Kitzingen, __________________________ ______________________________________ Lothar Pfeuffer, general manager © 2017 – Pfeuffer GmbH Seite 22 von 22 Revision 3...