5.4 Design standard use period

Design standard use period is established for the product. (See the table below.)
Use of the product beyond this period may result in personal injury or property damage.
- Pump...10 years
Standard Conditions of Use
SR140P25
SR140P38
SR140P50
SR125D13
Application
Pumping grease
Season
Spring and Fall
Temperature
20°C
Material being pumped
Lithium Soap Grease: No.1
Supply air pressure
0.5MPa
Daily Amount of Material being pumped
447L
292L
235L
660L
(Discharge volume)
Operating Days per year
260 days (5 days a week)