NEC PASOLINK Training Course page 98

Digital microwave radio system
Table of Contents

Advertisement

ROI-S04488
Step
12. Alarm table 3/3
28. TX PWR ALM 1
29. TX PWR ALM 2
30. RX LEV ALM 1
31. RX LEV ALM 2
32. APC1 ALM 1
33. APC1 ALM 2
34. APC2 ALM 1
35. APC2 ALM 2
36. IF INPUT ALM 1
37. IF INPUT ALM 2
38. MAINT
39. TX SEL 1
40. TX SEL 2
41. RX SEL 1
42. RX SEL 2
43. MDP CPU ALM 1
44. MDP CPU ALM 2
Select item No. (1-44, 0:no change):
Notes: 1. Alarm table displayed on the LCT depends on system
configuration.
2. Alarms signals C1 to C6 will appear on the ALM/AUX
ALM terminals.
C1: 1, 2 and 3 pins
C2: 4, 5 and 6 pins
C3: 7, 8 and 9 pins
C4: 10, 11 and 12 pins
C5: 20, 21 and 22 pins
C6: 23, 24 and 25 pins
3. Indications "OUT" and "–" mean that the alarm is
"outputted" or "not outputted", respectively.
4. Indication "MASK" means that if this "MASK" is
pressed, the alarm usually issued when the equipment
had been set to maintenance mode can be disabled.
5 Selecting item No. changes depending on the mounted
modules.
32
Enter item No. and press the "Enter" key for setting, if not, press
the "0" key and "Enter" key to go back to the Setting menu,
Procedure
C1
C2
C3
OUT
OUT
OUT
OUT
OUT
OUT
OUT
OUT
MASK
MASK
MASK
OUT
OUT
OUT
OPERATION
C4
C5
C6
OUT
OUT
MASK
MASK
OUT
OUT
3-41