Siren Command Definitions - Whelen Engineering Company IPS 400 Product Manual

In-plant personnel warning system
Table of Contents

Advertisement

Command
___________________________________________________________________________
00H Clear
01H Wail
02H Attack
03H Alert
04H Public Address
05H Air-Horn
06H Hi-Lo
07H Whoop
08H Wail-2 (noon test)
09H North
0AH East
0BH South
0CH West
0DH Clockwise
0EH Counter clockwise
0FH Silent test
10H Clear
11H Message 13
12H Message 14
13H Message 15
14H Message 16
15H Rotor position
16H Counter
17H Clear counter
18H Arm system
19H Dis-arm system
1AH Siren on
1BH Siren off
1CH Signal/Noise Req.
1DH Signal/Noise Status
1EH Test Clear
1FH Status Request
20H Clear
21H Battery/AC
22H Battery/Temperature
23H Instant Status
24H Transmit Off
25H Strobe Test
26H not used
27H Wind Shift
28H Reset Wind & Temp.
29H Reset Rainfall
2AH Weather
2BH Temperature
2CH Wind
2DH Rainfall
2EH Humidity
2FH Barometer

Siren Command Definitions

Function
Clears any event in progress.
Tone Warning.
Tone Warning.
Tone Warning.
Live Public Address.
Tone Warning.
Tone Warning.
Tone Warning.
Tone Warning, short tone.
Positioning command to North.
Positioning command to IPSt.
Positioning command to South.
Positioning command to West.
Positioning command to increment 45° clockwise.
Positioning command to increment 45° counter-clockwise.
Initiates the diagnostic Silent Test, producing a Status response.
Clears any event in progress.
Initiates digital voice message 13, for an RSDVM module.
Initiates digital voice message 14, for an RSDVM module.
Initiates digital voice message 15, for an RSDVM module.
Initiates digital voice message 16, for an RSDVM module.
Rotor/speaker position request.
Tone activation software counter request.
Clears the software tone activation counter to zero.
Arms the Instant Status response.
Disables the Instant Status response.
Enables the tone generator and digital voice.
Disables the tone generator, digital voice is active.
Executes the Signal to Noise check in a Remote Siren.
Signal to Noise reading request.
Clears LEDs
Retrieves the Status byte.
Clears any event in progress.
Requests battery voltage and AC voltage mIPSurements.
Requests battery voltage and cabinet temp. mIPSurements.
Get real time (instant) status of Remote Siren Station.
Disables the transmit repeat feature during Instant Status.
StrobeVisor™ only. 4 to 5 flash test period.
Greatest directional shift, on a sliding 10 minute window.
Resets the wind and temperature values.
Resets the rainfall value.
Requests outside temperature, wind direction, wind speed, and rainfall.
Requests cabinet temperature, outside temperature, low peak, and high peak
(peak values since last reset).
Requests wind direction, speed, and peak (peak value since last reset).
Requests totalized rainfall since last reset.
Requests the humidity reading.
Requests the barometric pressure.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ips 800

Table of Contents