WHEN THE DOORS ARE OPEN
unheated only
for outdoor use
unheated only
Installation & Maintenance Instructions

TABLE OF CONTENTS

I. UNCRATING ............................................................................................................................................................................................................................................................. 2
II. MOUNTING INSTRUCTIONS ............................................................................................................................................................................................................................... 3
III. WALL MOUNTING ................................................................................................................................................................................................................................................ 4
IV. SUSPENDED MOUNTING ................................................................................................................................................................................................................................... 4
V. VERTICAL MOUNTING .......................................................................................................................................................................................................................................... 5
VI. TANDEM MOUNTING BRACKETS (for Vertical Mounting) ............................................................................................................................................................................ 5
VII. ELECTRICAL CONNECTIONS ............................................................................................................................................................................................................................. 6
VIII. MECHANICAL CONNECTIONS ........................................................................................................................................................................................................................ 6
IX. OPERATION INSTRUCTIONS ............................................................................................................................................................................................................................. 7
INTELLISWITCH™ QUICK START OPERATION .....................................................................................................................................................................................................10
X. MAINTENANCE AND CLEANING ........................................................................................................................................................................................................................ 8
XI. SERVICE ................................................................................................................................................................................................................................................................ 8
XII. TROUBLESHOOTING ........................................................................................................................................................................................................................................ 14
A. INTERCONNECT OPERATION (daisy chain) ..........................................................................................................................................................................................15
B. REMOTE MOUNTED TOUCHSCREEN or TABLET ....................................................................................................................................................................................15
C. BUILDING MANAGEMENT SYSTEM (BMS) INTEGRATION (BACnet or Modbus) .............................................................................................................................15
XIV. WARRANTY ....................................................................................................................................................................................................................................................... 16
Berner International has been saving energy and creating healthy, comfortable environments for our customers
for over 60 years. Berner offers unmatched quality, performance, and dependability-not to mention our service.
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
IMPORTANT INSTRUCTIONS
®
save energy & create healthy, comfortable environments
Thank you for choosing Berner.
At Berner, we stand behind our products.
Industrial Direct Drive
Air Curtain Series
#IDC12 & IDC14
Connect with
BERNER AIR
SET UP
CONTROL
TROUBLESHOOT
©Copyright, 2025 Berner International
BERNER.COM
II-230 EUROPE
March, 2025

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IDC12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Berner IDC12

  • Page 1: Table Of Contents

    Thank you for choosing Berner. Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years. Berner offers unmatched quality, performance, and dependability—not to mention our service. At Berner, we stand behind our products.
  • Page 2: Uncrating

    (or illuminates), immediately turn the heater off and inspect for any objects on or adjacent to the heater that may have blocked the airflow or otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING). 457mm 457mm Model: IDC12 Model: IDC14 380mm 380mm I.
  • Page 3: Mounting Instructions

    IDC12-3108 with door operation. IDC12-2120 B. The IDC12/IDC14 Series air door is designed to be an IDC12-3120 effective barrier against cold drafts in the winter and hot IDC12-3132 air in the summer. To achieve optimum protection, the...
  • Page 4: Wall Mounting

    See Figure 3. Or, the unit may be attached using an optional wall mounting bracket or a combination of extension and wall mounting brackets (available from Berner) attached to the holes on the top of Figure 2 the end plate and the wall. See Figure 4.
  • Page 5: Vertical Mounting

    Two Brackets are required. C. To vertically mount a IDC12/IDC14 Series unit using optional Floor Mounting Brackets, bolt brackets on the inside of the...
  • Page 6: Electrical Connections

    VII. ELECTRICAL CONNECTIONS All electrical wiring and connections MUST be performed by qualified personnel in accordance with the EU Directive 50110 and International Electrotechnical Standard IEC 60364 and local codes and regulations A. Check the rating nameplate on the top of the unit for supply voltage and current requirements.
  • Page 7: Operation Instructions

    IX. OPERATING INSTRUCTIONS Connect with This air curtain comes with a built-in Intelliswitch™ digital BERNER AIR controller with touchscreen display and the Berner AIR® BASIC SET UP smart control and app to control and schedule fan activation, CONTROL fan speed selection, heat activation, and more. The Berner TROUBLESHOOT BERNER.COM...
  • Page 8: Maintenance And Cleaning

    CLEAR OF THE UNIT OR WEAR SAFETY GOGGLES AS LOOSE DEBRIS MAY BE PRESENT AND MAY EXIT THE Any service performed on the IDC12/IDC14 Series air curtain NOZZLE. MUST be done by qualified personnel. Berner air curtains require very little servicing.
  • Page 9 A. BLOWER MODULE REMOVAL 1. Disconnect and lockout power from the unit. 2. Remove the Bottom Access Panel. The Inlet Screen and Top Access Panel do not need to be removed, but taking them off can make the process easier. 3.
  • Page 10: Quick Start Instructions

    QUICK START INSTRUCTIONS For your Berner Air Curtain with Intelliswitch™ Indicators area: -Firmware Update -Warning Unit ID Clock Temperature Bluetooth Indicator Wireless Network Opening Counter Ethernet Network Heat Indicator Indicator HOME SCREEN FAN SPEED SETTINGS To reach the “HOME” Screen, You can adjust your settings by press the "+"...
  • Page 11: Mode Settings

    Days (7/7 Week) NOTE: You can use the button to cancel your action. Press the adjacent tiles on other sides to navigate through the menu. Berner International www.berner.com 800.245.4455 111 Progress Ave. / New Castle / PA / 16101 / USA -11-...
  • Page 12: Troubleshooting

    XII. TROUBLESHOOTING SYMPTOMS CAUSE REMEDY • Power supply line open (no power) • Check power source, check service disconnect, NO AIR check method of control in ON position • Fuse blown/circuit breaker tripped • Replace fuse(s)/reset breaker • Motor overload tripped •...
  • Page 13: Appendix

    90m (provided by others). C. Building Management System (BMS) Integration (BACnet or Modbus) This unit is equipped with the Berner AIR™ BMS smart control & app, and is BACnet and Modbus compatible. 1. To connect wirelessly to the Building Management...
  • Page 14 C€ Manufacturer/lmporter: Name: Berner International Address: Castle, PA 16101, USA 111 Progress Ave. New Phone/Fax 724-658-3551 Declares that the product: EUT Description: IDC12-5192AV-F Model Number: IDC12 technical standard: Conforms following RoHS II EN 55014-2:1997+A2:2008 EN 60204-1:2006 EN 63000:2016 EN 50566:2017 EN 61000-6-1:2007 EN 301 489-1 V 2.2.3...
  • Page 15: Interconnect Operation (Daisy Chain)

    Declaration of Conformity C€ Manufacturer/lmporter: Name: Berner International Address: Ave. New Castle, PA 16101, USA Progress Phone/Fax 724-658-3551 Declares that the product: EUT Description: IDC14-5192AV-F Model Number: IDC14 Conforms the following technical standard: RoHS II EN 55014-2:1997+A2:2008 EN 60204-1:2006 EN 50566:2017...
  • Page 16: Warranty

    XIII. WARRANTY Berner International (“The Company”) warrants all new equipment to be free of defects in workmanship and material for a period of five years (5 years) from the original date of shipment, provided the equipment has been properly cared for, installed and operated in accordance with the limits specified on the nameplate and The Company’s instructions.