Panasonic DVC PRO Studio AJ-D950P Service Manual page 127

Vtr/analog video interface kit
Table of Contents

Advertisement

3. Set the values as follows.
E02 REC FREQ L1 -100
E04 REC FREQ L2 -100
4. Change the item E01 REC CURR L1 and E03 REC CURR L2 until
just achieve the saturation level at 2.5MHz.
5. Adjust E02 REC FREQ L1 and E04 REC FREQ L2 so that the level at
10MHz is maximum.
6. Store the signal in the TRACE-B.
7. Adjust following items so that the waveform becomes TRACE-A of
the following figure.
Adjustment items
E01 REC CURR L1 , E03 REC CURR L2
E02 REC FREQ L1 , E04 REC FREQ L2
8. Add "+ 90" to the value of E01 REC CURR L1 and E03 REC CURR L2
(Ex. In case of -50
9. After adjustment, compare the spectrum of Master Playback and
Confidence Playback.
6.6.37. Comparison of the Spectrum of Master PB and Confidence PB (25M Lch)
+40)
127