3-6-7
Neutral Position Adjustment
Board
SERVO
Specification
2.5+/-0.1V
Test Point
TP201(SERVO:F1)
Adjustment Tension Regulator Board Base Position
Mode
STOP
M. EQ.
Digital Volt Meter
VFK1208(Black, with a hole)
1.
Remove 4 screws on the Front Loading Unit
and Remove it, then set the VFK1208
(Black , with a hole).
2.
Set the VTR in the no tape loading mode.
3.
Adjust the Tension Regulator Board Base
Position so that the voltage at TP201 is in
the specification in STOP mode. To adjust
the Tension Regulator Board Base Position,
loosen the screw A and move the knob D
portion
by
a
magnetization and tighten the screw A.
4.
To set the VTR in no tape loading mode, set
the DIP SW1 at the rear panel ON to open
the service menu. Then select "T REEL
TRQ" and press JOG/SHTL key. During
adjustment JOG/SHTL key must be hold.
Do not touch the adjustment drive to the
Reel FG magnet.
screw
driver
without