HYDAC ELECTRONIC HNS 3000 Operation Manual

HYDAC ELECTRONIC HNS 3000 Operation Manual

Level switch, with io-link interface
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Bedienungsanleitung
(Originalanleitung)
Operation manual
(Translation of original
instructions)
Niveauschalter
Level switch
HNS 3000
Mit IO-Link Schnittstelle
With IO-Link Interface

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HNS 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for HYDAC ELECTRONIC HNS 3000

  • Page 1 Niveauschalter Level switch HNS 3000 Mit IO-Link Schnittstelle With IO-Link Interface Bedienungsanleitung (Originalanleitung) Operation manual (Translation of original instructions)
  • Page 2: Table Of Contents

    Bestimmungsgemäßer Gebrauch / vorhersehbarer Fehlgebrauch ......6 Verpflichtung des Betreibers vor der Inbetriebnahme ..........6 Personalauswahl und Qualifikation; Grundsätzliche Pflichten ......... 6 Organisatorische Maßnahmen ................7 Funktionen des HNS 3000 ................7 Montage ......................8 Allgemeine Montagehinweise.................. 8 Zusätzliche Montagehinweise ................. 9 Inbetriebnahme ....................
  • Page 3 HNS 3000 IO-Link Seite 3 13.1 Hauptmenü......................20 13.2 Erweiterte Funktionen ................... 21 Ändern der Grundeinstellungen ............... 23 Rücksetzen der Spitzenwerte ..............23 Programmierfreigabe ................23 16.1 Allgemeines ......................23 16.2 Ändern der Programmierfreigabe ................23 Meldungen ....................24 17.1 Fehlermeldungen ....................24 17.2 Sonstige Meldungen .....................
  • Page 4: Vorwort

    HNS 3000 IO-Link Vorwort Für Sie, den Benutzer unseres Produktes, haben wir in dieser Dokumentation die wichtigsten Hinweise zum Bedienen und Warten zusammengestellt. Sie dient Ihnen dazu, das Produkt kennen zu lernen und seine bestimmungs- gemäßen Einsatzmöglichkeiten optimal zu nutzen.
  • Page 5: Sicherheitshinweis

    HNS 3000 IO-Link Seite 5 Sicherheitshinweis Überprüfen Sie vor der Inbetriebnahme den Zustand des Gerätes sowie des mitgelie- ferten Zubehörs. Lesen Sie vor der Inbetriebnahme des Gerätes die Bedienanleitung und stellen Sie sicher, dass das Gerät für Ihre Anwendung geeignet ist.
  • Page 6: Bestimmungsgemäßer Gebrauch / Vorhersehbarer Fehlgebrauch

    HNS 3000 IO-Link Das Symbol bezeichnet wichtige Informationen bzw. Merkmale und Anwendungstipps des verwendeten Produkts. Das Symbol bedeutet, dass entsprechende ESD-Schutzmaßnahmen nach DIN EN 100 015-1 zu beachten sind. (Herbeiführen eines Potentialausgleichs zwischen Körper und Geräte- masse sowie Gehäusemasse über einen hochohmigen Widerstand (ca.
  • Page 7: Organisatorische Maßnahmen

    System müssen stets in lesbarem Zustand erhalten werden.  Reparaturen dürfen nur vom Hersteller, oder einer vom Hersteller autorisierten Stelle bzw. Person vorgenommen werden. Funktionen des HNS 3000 Je nach Ausführung bietet das Gerät folgende Funktionen:  Unterstützt IO-Link-Spezifikation V1.1 und V1.0 ...
  • Page 8: Montage

    HNS 3000 IO-Link Montage 6.1 Allgemeine Montagehinweise Der elektronische Niveauschalter HNS 3000 kann über ein G3/4 A ISO1179-2 Gewinde- anschluss direkt in den Tankdeckel montiert werden. Zur optimalen Ausrichtung ist eine Verdrehung um 340° in der Längsachse, sowie um 270° im Display inklusive der Bedientasten möglich.
  • Page 9: Zusätzliche Montagehinweise

     Zeigt die Anzeige einen Wert > 0 oder liegt eine Überfüllung vor, so wird das Niveau nach und nach - durch Ablassen der Flüssigkeit – verringert, bis in der Anzeige der Wert 0 angezeigt wird. Nach der Entnahme des HNS 3000 aus dem Tank ist die Vorgehensweise wie zuvor beschrieben.
  • Page 10: Bedienelemente Des Hns 3000

    Nach dem Start befindet sich der Druckschalter im SIO-Mode (Standard IO-Mode). In diesem Modus hat Pin 4 die Funktion eines Schaltausganges.  Die Mittel-LED leuchtet dauerhaft. Gemäß Kapitel 13 Grundeinstellungen kann das Verhalten des HNS 3000 an die jeweilige Applikation angepasst werden. Stand 02.04.2020 Mat.Nr.
  • Page 11: Sdci-Mode

    Im SDCI-Mode findet eine zyklische Übertragung der Prozessdaten zu dem angeschlossenen IO-Link-Master über den Kommunikations-Pin 4 statt. Der HNS 3000 liefert je nach Ausführung - ohne oder mit zusätzlichem Temperaturfühler - eine Prozessdatenbreite von 2 bzw. 4 Byte. Für den eigentlichen Messwert („PDV“ = „Process Data Value“) werden je 14 Bit verwendet.
  • Page 12: Parametrierung

    Als weitere Datenquelle für IODDs kann zudem der IODD finder verwendet werden: (https://ioddfinder.io- link.com/#/productvariants?vendorName=%22HYDAC%20ELECTRONIC%20GmbH%22) 10.1 Manuelle Parametrierung am Gerät Der HNS 3000 kann über die Bedienelemente am Gerät parametriert werden. Menüführung siehe Kapitel 13 Grundeinstellungen. Stand 02.04.2020 Mat.Nr. 669945 D...
  • Page 13: Parametrierung Mit Hydac Programmiergerät Hpg P1-000

    HNS 3000 IO-Link Seite 13 10.2 Parametrierung mit HYDAC Programmiergerät HPG P1-000 (Anschluss mit Standardkabel) HPG P1 Device Q1 / C 10.3 Parametrierung mit HYDAC Programmieradapter ZBE P1-000 (Anschluss mit Standardkabel) Q2 / QA ZBE P1 Device Q1 / C 10.4 Parametrierung im SDCI-Mode...
  • Page 14: Darstellung Der Digitalanzeige

    HNS 3000 IO-Link Darstellung der Digitalanzeige Darstellung Bezeichnung Darstellung ASCII 7-Segment-Anzeige Schaltpunkt, Ausgang 1 Rückschaltpunkt, Ausgang 1 Schaltpunkt, Ausgang 2 Rückschaltpunkt, Ausgang 2 Niveau / Temperatur, Fenster oberer Wert, Ausgang 1 Niveau / Temperatur, Fenster unterer Wert, Ausgang 1 Niveau / Temperatur,...
  • Page 15 HNS 3000 IO-Link Seite 15 Einheit °C Einheit °F Niveauoffset Min-Wert für Niveau Max-Wert für Niveau Min-Wert für Temperatur Max-Wert für Temperatur Fehleranzeige Rücksetzen Nein Reset Min / Max-Wert rS.HL rS. k L Programmiersperre Tasten verriegelt Tasten entriegelt Free FRee...
  • Page 16: Ausgangsverhalten

    HNS 3000 IO-Link Ausgangsverhalten 12.1 Schaltausgänge Der HNS 3000 IO-Link verfügt über 2 Schaltausgänge, deren Schaltverhalten (Window- Mode oder Two-Point-Mode) parametriert werden können. Ergänzend zu der IO-Link Smart Sensor Profile Specification kann bei HYDAC IO-Link Sensoren eine Schalt- und Rückschaltverzögerung parametriert werden.
  • Page 17: Window-Mode - Einstellung Auf Fensterfunktion (Fno / Fnc)

    HNS 3000 IO-Link Seite 17 12.1.2 Window-Mode - Einstellung auf Fensterfunktion (Fno / Fnc) Die Fensterfunktion ermöglicht es, einen Bereich zu überwachen. Zu jedem Schalt- ausgang können jeweils ein oberer und ein unterer Schaltwert eingegeben werden, die den Bereich bestimmen.
  • Page 18: Einstellbereiche Für Die Schaltausgänge

    HNS 3000 IO-Link 12.2 Einstellbereiche für die Schaltausgänge Messbereich/ Untere Grenze Obere Grenze Mindestabstand Schrittweite* Sondenlänge von RP (FL) von SP (FH) zw. RP und SP bzw. FL und FH in cm in cm in cm in cm 17,8 / 25,0...
  • Page 19: Analogausgang

    Analogausgang verwendet, dann darf dieser nicht mit dem IO-Link Master verbunden werden, da dieser keine Analogsignale unterstützt. Grundeinstellungen Zur Anpassung an die jeweilige Applikation kann das Verhalten des HNS 3000 über mehrere Grundeinstellungen verändert werden. Diese sind zu einem Menü zusammen- gefasst.
  • Page 20: Hauptmenü

    HNS 3000 IO-Link 13.1 Hauptmenü Der Bereich wird nicht ange- zeigt, wenn in „Erweiterte Funktionen“ unter „ou2“ „i“ oder „u“ eingestellt ist. Stand 02.04.2020 Mat.Nr. 669945 D HYDAC ELECTRONIC GMBH...
  • Page 21: Erweiterte Funktionen

    HNS 3000 IO-Link Seite 21 13.2 Erweiterte Funktionen Der Bereich wird nicht ange- zeigt, wenn „Erweiterte Funktionen“ unter „ou2“ „i“ oder „u“ eingestellt ist. Stand 02.04.2020 Mat.Nr. 669945 D HYDAC ELECTRONIC GMBH...
  • Page 22 HNS 3000 IO-Link Stand 02.04.2020 Mat.Nr. 669945 D HYDAC ELECTRONIC GMBH...
  • Page 23: Ändern Der Grundeinstellungen

    HNS 3000 IO-Link Seite 23 Ändern der Grundeinstellungen HINWEIS: Erfolgt ca. 60 Sekunden lang keine Tastenbetätigung wird das Menü automatisch beendet, ohne dass eventuelle Änderungen wirksam werden. Rücksetzen der Spitzenwerte Die Spitzenwerte des Niveaus können zurückgesetzt werden. • In den Erweiterten Funktionen die Taste "" betätigen bis der Menüpunkt „rSHL“...
  • Page 24: Meldungen

    HNS 3000 IO-Link • "mode" -Taste betätigen. • Hier kann zwischen Programmierung frei „FREE“ und Programmierung gesperrt „Loc“ entschieden werden mit "" bzw. ““ erfolgt der Wechsel zwischen den Möglichkeiten. • Einstellung mit der "mode"-Taste quittieren. Meldungen 17.1 Fehlermeldungen Wird ein Fehler erkannt, so erscheint eine entsprechende Fehlermeldung, die mit einem beliebigen Tastendruck quittiert werden muss.
  • Page 25: Sonstige Meldungen

    HNS 3000 IO-Link Seite 25 17.2 Sonstige Meldungen Weitere Meldungen können auf dem Display erscheinen, die nicht mit einem beliebigen Tastendruck quittiert werden können. Mögliche Meldungen, wenn der HNS noch nicht in Betrieb genommen war: Blinkende Anzeige aller Mittel-LED’s Der HNS erkennt einen nicht definierten Zustand, d.h. das Niveau des Abhilfe: Messmediums liegt außerhalb des aktiven Messbereiches.
  • Page 26: Anschlussbelegung

    HNS 3000 IO-Link Anschlussbelegung M12x1, 4-polig Q1/C Q2/QA Signal Bezeichnung Q2/QA Schaltausgang (SP2) / Analogausgang Q1/C Schaltausgang (SP1) / IO-Link Kommunikation Stand 02.04.2020 Mat.Nr. 669945 D HYDAC ELECTRONIC GMBH...
  • Page 27: Technische Daten

    HNS 3000 IO-Link Seite 27 Technische Daten Eingangskenngrößen Messbereich (inch) (7,00) (8,15) (11,70) (13,30) (17,65) (25,90) Stablänge (inch) (9,84) (11,02) (14,57) (16,14) (20,47) (28,74) Max. Änderungsgeschwindigkeit des Niveaus Beliebig Mechanischer Anschluss G ¾“ ISO 1179-2 Anzugsdrehmoment, empfohlen 30 Nm Medien berührende Teile Stab: Edelstahl 1.4571...
  • Page 28 HNS 3000 IO-Link IO-Link-spezifische Daten: Download der IO Device Description (IODD) unter: https://ioddfinder.io-link.com/#/ Features Block Parameter Data Storage Profile Characteristic 0x0001 (Device Profile: Smart Sensor), 0x8000 (Function Class: Device Identification), 0x8001 (Function Class: Binary Data Channel), 0x8002 (Function Class: Process Data Variables)
  • Page 29: Typenschlüssel

    HNS 3000 IO-Link Seite 29 Typenschlüssel HNS 3 X 2 6 – F31 –XXXX – 000 Serien-Nr. (werksintern festgelegt) Temperaturfühler 1 = Mit Temperaturfühler 2 = Ohne Temperaturfühler Anschlussart, mechanisch 2 = G3/4 A ISO1179-2 Anschlussart, elektrisch 6 = Gerätestecker M12x1, 4-pol.
  • Page 30: Zubehör

    HNS 3000 IO-Link Zubehör Elektrischer Anschluss ZBE 06 (4-pol.) Kupplungsdose M12x1, abgewinkelt Kabeldurchmesser: 2,5 .. 6,5 mm (0,1 .. 0,26 inch) Material-Nr.: 6006788 ZBE 06-02 (4-pol.) Kupplungsdose M12x1, abgewinkelt mit 2 m (78,7 inch) Leitung, Material-Nr.: 6006790 ZBE 06-05 (4-pol.),...
  • Page 31: Geräteabmessungen

    HNS 3000 IO-Link Seite 31 Geräteabmessungen 4-pol. Einbauraum ∅ 54 Bezeichnung (inch) (inch) (inch) (inch) (inch) (inch) Inaktiver Bereich ca. 34 ca. 34 ca. 34 ca. 34 ca. 34 ca. 34 unten (ca. 1,34) (ca. 1,34) (ca. 1,34) (ca. 1,34) (ca.
  • Page 32: Abkürzungsverzeichnis

    HNS 3000 IO-Link Abkürzungsverzeichnis Wert-Fenster oberer Wert Wert-Fenster unterer Wert Fensterfunktion Öffner Fensterfunktion Schließer Full Scale Hystesefunktion Öffner Hysteresefunktion Schließer Hyst Hysterese IODD IO Device Description ISDU Indexed Service Data Unit Ausgangsfunktion Rückschaltpunkt SDCI Single-drop digital communication interface Standard IO-Modus...
  • Page 33: Kontakt

    HNS 3000 IO-Link Seite 33 Kontakt HYDAC ELECTRONIC GMBH Hauptstr. 27 D-66128 Saarbrücken Germany Web: www.hydac.com E-Mail: electronic@hydac.com Tel.: +49 (0)6897 509-01 Fax.: +49 (0)6897 509-1726 HYDAC Service Für Fragen zu Reparaturen steht Ihnen der HYDAC Service zur Verfügung. HYDAC SERVICE GMBH Hauptstr.
  • Page 34: Anhang / Annex: Iodd Einstellparameter / Iodd Setting Parameters

    HNS 3000 IO-Link Anhang / Annex: IODD Einstellparameter / IODD Setting Parameters Die Einstellparameter des HNS 3000 am The setting parameters of the HNS 3000 Beispiel eines Gerätes mit 250 mm Fühler- using the example of a device with a länge und integriertem Temperaturfühler...
  • Page 35 HNS 3000 IO-Link Seite 35 Standard Variable "Standard Command" index=2 id=V_SystemCommand data type: 8-bit UInteger allowed values: 128 = Device Reset, 129 = Application Reset, 130 = Restore Factory Settings, 160 = Reset Primary Min/Max, 161 = Reset Secondary Min/Max, 164 = Reset All...
  • Page 36 HNS 3000 IO-Link Variable "BDC1 Behavior" index=61 id=V_Bdc1Behavior data type: 32-bit Record (subindex access not supported) access rights: rw modifies other variables excluded from data storage allowed default subindex data type mod. other var. name description offset values value 0 = Default, 1...
  • Page 37 HNS 3000 IO-Link Seite 37 octet bit offset 31 - 24 23 - 16 15 - 8 7 - 0 subindex element bit 7 - 0 7 - 0 15 - 8 7 - 0 Die Schaltbits BDCx sowie die physischen Schaltausgänge SPx sind intern miteinander gekoppelt.
  • Page 38 HNS 3000 IO-Link Variable "Primary Value SP2" index=65 id=V_PrimaryValueSp2 data type: 112-bit Record (subindex access not supported) access rights: rw modifies other variables data default subindex allowed values mod. other var. name description offset type value 0 = Normally 8-bit...
  • Page 39 HNS 3000 IO-Link Seite 39 octet 111 - bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 subindex element bit 7 - 0 7 - 0...
  • Page 40 HNS 3000 IO-Link Variable "SP States" index=72 id=V_SpStates data type: 8-bit Record (subindex access not supported) access rights: ro dynamic allowed mod. subindex data type default value name description offset values other var. Boolean false Primary Value SP1 Boolean false...
  • Page 41 HNS 3000 IO-Link Seite 41 Variable "Display Mapping" index=75 id=V_DspMapping data type: 8-bit UInteger allowed values: 0 = Primary Value, 1 = Secondary Value default value: 0 access rights: rw octet bit offset 7 - 0 element bit 7 - 0 Variable "Primary Value Display Unit"...
  • Page 42 HNS 3000 IO-Link Variable "Secondary Value Range" index=81 id=V_SecondaryValueRange data type: 72-bit Record (subindex access not supported) access rights: ro allowed default mod. subindex data type name description offset values value other var. 16-bit Integer -250 Lower Value 16-bit Integer...
  • Page 43 HNS 3000 IO-Link Seite 43 Variable "Secondary Value" index=85 id=V_SecondaryValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value Boolean...
  • Page 44 HNS 3000 IO-Link Variable "Secondary Minimum Value" index=89 id=V_SecondaryMinValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value Boolean false...
  • Page 45 HNS 3000 IO-Link Seite 45 Variable "Secondary Maximum Value" index=93 id=V_SecondaryMaxValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value...
  • Page 46 HNS 3000 IO-Link Variable "BDC3 Behavior" index=16385 id=V_Bdc3Behavior data type: 32-bit Record (subindex access not supported) access rights: rw modifies other variables excluded from data storage allowed default subindex data type mod. other var. name description offset values value 0 = Default,...
  • Page 47 HNS 3000 IO-Link Seite 47 octet bit offset 31 - 24 23 - 16 15 - 8 7 - 0 subindex element bit 7 - 0 7 - 0 15 - 8 7 - 0 ErrorTypes Additional Code Name Description...
  • Page 48 HNS 3000 IO-Link Process Data Formatting Formatting for Process Data id=PI_PdIn Subindex 1: Subindex 2: Subindex 3: * 0.1 + 0 cm Dec.1 Subindex 4: Subindex 5: Subindex 6: * 0.1 + 0 °C Dec.1 Events Code Type Name Description...
  • Page 49               Level switch     HNS 3000       With IO-Link Interface       Operation manual (Translation of original instructions)
  • Page 50 Functions of the HNS 3000 ................. 7 Installation ....................8 General installation notes ..................8 Additional installation instructions ................9 Commissioning .................... 9 Operating elements of the HNS 3000 ............10 Operation modes ..................10 SIO mode ......................10 SDCI mode......................11 Parameterisation ..................12 10.1 Manual parameterisation on the device ..............
  • Page 51 HNS 3000 IO-Link page 3 13.1 Main menu ......................20 13.2 Add-on functions ....................21 Changing the basic settings ..............23 Resetting the peak values ................. 23 Program enable ..................23 16.1 General overview ....................23 16.2 Changing the Programming Enable ..............23 Messages ....................
  • Page 52: Preface

    HNS 3000 IO-Link Preface This manual provides you, as user of our product, with key information on the operation and maintenance of the equipment. It will acquaint you with the product and assist you in obtaining maximum benefit in the applications for which it is designed.
  • Page 53: Safety Information

    HNS 3000 IO-Link page 5 Safety information Before commissioning, check the instrument and any accessories supplied. Before commissioning, please read the operating instructions. Ensure that the instrument is suitable for your application. If the instrument is not handled correctly, or if the operating instructions and specifications are not adhered to, damage to property or personal injury can result.
  • Page 54: Intended Use / Foreseeable Misuse

    HNS 3000 IO-Link The symbol indicates important information or features and application suggestions for the product used The symbol means that appropriate ESD-protective measures must be considered according to DIN EN 100 015-1. (Cause of a potential equalization between body and device-mass as well as the housing-mass about a high-impedance resistance (approx.
  • Page 55: Organisational Measures

     Repairs may only be undertaken by the manufacturer or a facility or person authorized by the manufacturer. Functions of the HNS 3000 Depending on the model, the instrument has the following functions:  Supports IO-Link specifications V1.1 and V1.0 ...
  • Page 56: Installation

    Installation 6.1 General installation notes The electronic level switch HNS 3000 can be mounted directly inside the tank cover by means of a G3/4 A ISO1179-2 (male) thread connection. To ensure optimal positioning, the unit can be rotated by 340° about its long axis, and the display and key pad can be rotated by 270°.
  • Page 57: Additional Installation Instructions

    If the system reports low level, the level will gradually be filled up by a fluid until 0 is displayed. Then, the HNS 3000 is removed from the tank and the fluid level inside the tank is determined by a measuring unit. Depending on the model, this value is displayed in the menu in "cm"...
  • Page 58: Operating Elements Of The Hns 3000

    After start-up, the pressure switch is in SIO mode (standard I/O mode). In this mode, Pin 4 serves as a switching output.  The centre LED is constantly lit. According 13 Basic Settings the behaviour of the HNS 3000 can be adjusted to Chapter the corresponding application. Edition: 2020-04-02 Part no.: 669945 E...
  • Page 59 In the SDCI mode a transmission of the process data is performed cyclically via the communication pin 4 to the connected IO-Link master. The HNS 3000 provides a process data width of 2 or 4 bytes, depending on the model version, regardless if with or without additional temperature switch. 14 bits are used for each actual measured value ("PDV"...
  • Page 60 HNS 3000 IO-Link Octet 2 bit offset Subindex element Octet 3 bit offset sub index element NOTICE: Direct access via the subindex number is not supported. In the version without a temperature sensor the octets 1 and 2 represent the fluid level.
  • Page 61 HNS 3000 IO-Link page 13 10.2 Parameterisation with HYDAC programming device HPG P1-000 (Connection via standard cable) HPG P1 Device Q1 / C 10.3 Parameterisation by means of HYDAC programming adapter ZBE P1-000 (Connection via standard cable) Q2 / QA...
  • Page 62 HNS 3000 IO-Link Reading the digital display Representation on ASCII Code 7-segment display representation Switch point, output 1 Switch-back point, output 1 Switch point, output 2 Switch-back point, output 2 Level / temperature, window upper value, output 1 Level / temperature,...
  • Page 63 HNS 3000 IO-Link page 15 Unit °F Level offset Min value for level Max value for level Min value for temperature Max value for temperature Error indication Reset Reset min/max value rS.HL rS. k L Programming disable Buttons locked Keys unlocked...
  • Page 64: Output Signals

    HNS 3000 IO-Link Output Signals 12.1 Switching outputs The HNS 3000 IO-Link has 2 switching outputs whose switching behaviour (window mode or two-point mode) is parameterisable. In addition to the IO-Link Smart Sensor Profile Specification, a switch and switch-back delay can be set in HYDAC IO-Link sensors.
  • Page 65: Window Mode - Window Function Setting (Fno / Fnc)

    HNS 3000 IO-Link page 17 12.1.2 Window mode - Window function setting (Fno / Fnc) The window function enables a range to be monitored. An upper and a lower switch point which defines the range can be assigned to each switching output.
  • Page 66: Setting Ranges For The Switching Outputs

    HNS 3000 IO-Link 12.2 Setting ranges for the switching outputs Measurement Lower limit of Upper limit of Minimum difference Increment* range / Probe RP (FL) SP (FH) betw. RP and SP length or FL and FH in cm in cm...
  • Page 67: Analogue Output

    IO-Link master, as it does not support analogue signals. Basic Settings The function of the HNS 3000 can be adapted to suit the particular application by altering several basic settings. These settings are combined in a menu. Edition: 2020-04-02 Part no.: 669945 E...
  • Page 68: Main Menu

    HNS 3000 IO-Link 13.1 Main menu The range is not displayed if "i" or "u" is pre-set under "ou2" "extended functions". Add-on functions Edition: 2020-04-02 Part no.: 669945 E HYDAC ELECTRONIC GMBH...
  • Page 69 HNS 3000 IO-Link page 21 13.2 Add-on functions The range is not displayed if "i" or "u" is pre-set under "ou2" in the "extended functions". Edition: 2020-04-02 Part no.: 669945 E HYDAC ELECTRONIC GMBH...
  • Page 70 HNS 3000 IO-Link Edition: 2020-04-02 Part no.: 669945 E HYDAC ELECTRONIC GMBH...
  • Page 71: Changing The Basic Settings

    HNS 3000 IO-Link page 23 Changing the basic settings NOTICE: If there has been no activity in this menu for approx. 60 seconds, the menu will automatically close and any changes you have made will not be applied. Resetting the peak values The peak values of the fluid level can be set back.
  • Page 72: Messages

    HNS 3000 IO-Link  You can choose between free programming "FREE" and locked programming "Loc". By pressing "" or ““ you can switch between these options.  Confirm by pressing the "mode" key. Messages 17.1 Error Messages If an error is detected, a corresponding error message appears which must be acknowledged by pressing any key.
  • Page 73: Other Messages

    HNS 3000 IO-Link page 25 17.2 Other messages Other messages that cannot be confirmed by pressing any key may also appear on the display. Possible message, if the HNS has not yet been in use: Flashing display of all centre LEDs.
  • Page 74: Pin Connection

    HNS 3000 IO-Link PIN connection M12x1, 4-pin Q1/C Q2/QA Signal Code Q2/QA Switching output (SP2) / Analogue output Q1/C Switching output (SP1) / IO-Link communication Edition: 2020-04-02 Part no.: 669945 E HYDAC ELECTRONIC GMBH...
  • Page 75: Technical Data

    HNS 3000 IO-Link page 27 Technical data Input data Measurement range (inch) (7.00) (8.15) (11.70) (13.30) (17.65) (25.90) Rod length (inch) (9.84) (11.02) (14.57) (16.14) (20.47) (28.74) Max. speed of the fluid level change No restrictions Mechanical connection G ¾“ ISO 1179-2...
  • Page 76 HNS 3000 IO-Link IO-Link-specific data: IO Device Description (IODD) download at: https://ioddfinder.io-link.com/#/ Features Block Parameters Data Storage Profile Characteristic 0x0001 (Device Profile: Smart Sensor), 0x8000 (Function Class: Device Identification), 0x8001 (Function Class: Binary Data Channel), 0x8002 (Function Class: Process Data Variables)
  • Page 77: Model Code

    HNS 3000 IO-Link page 29 Model code HNS 3 X 2 6 – F31 –XXXX – 000 Serial-no. (determined by manufacturer) Temperature probe 1 = Temperature probe included 2 = Temperature probe not included Mechanical connection 2 = G3/4 A ISO1179-2...
  • Page 78: Accessories

    HNS 3000 IO-Link Accessories Electrical connection ZBE 06 (4 pole) Mating connector M12x1, right- angled Cable diameter: 2.5 .. 6.5 mm (0.1 .. 0.26 inch) Part No.: 6006788 ZBE 06-02 (4 pole) Mating connector M12x1, right-angle with 2 m (78.7 inch) cable, Part No.: 6006790...
  • Page 79: Dimensions

    HNS 3000 IO-Link page 31 Dimensions 4 pole Cavity ø 54 Immersion depth at density 1 Code (inch) (inch) (inch) (inch) (inch) (inch) Inactive zone approx. 34 approx. 34 approx. 34 approx. 34 approx. 34 approx. 34 (lower end) (approx.
  • Page 80: List Of Abbreviations

    HNS 3000 IO-Link List of abbreviations: Value window upper value Value window lower value Window function, N/C Window function, N/O Full Scale Hysteresis function N/C Hysteresis function, N/O Hyst Hysteresis IODD IO Device Description ISDU Indexed Service Data Unit Output function...
  • Page 81: Contact Information

    HNS 3000 IO-Link page 33 Contact information HYDAC ELECTRONIC GMBH Hauptstr. 27 D-66128 Saarbruecken Germany Web: www.hydac.com E-Mail: electronic@hydac.com Tel.: +49 (0)6897 509-01 Fax.: +49 (0)6897 509-1726 HYDAC Service For enquiries regarding repairs, please contact HYDAC Service. HYDAC SERVICE GMBH Hauptstr.
  • Page 82: Anhang / Annex: Iodd Einstellparameter / Iodd Setting Parameters

    HNS 3000 IO-Link Anhang / Annex: IODD Einstellparameter / IODD Setting Parameters Die Einstellparameter des HNS 3000 am The setting parameters of the HNS 3000 Beispiel eines Gerätes mit 250 mm Fühler- using the example of a device with a länge und integriertem Temperaturfühler...
  • Page 83 HNS 3000 IO-Link page 35 Standard Variable "Standard Command" index=2 id=V_SystemCommand data type: 8-bit UInteger allowed values: 128 = Device Reset, 129 = Application Reset, 130 = Restore Factory Settings, 160 = Reset Primary Min/Max, 161 = Reset Secondary Min/Max, 164 = Reset All...
  • Page 84 HNS 3000 IO-Link Variable "BDC1 Behavior" index=61 id=V_Bdc1Behavior data type: 32-bit Record (subindex access not supported) access rights: rw modifies other variables excluded from data storage allowed default subindex data type mod. other var. name description offset values value 0 = Default, 1...
  • Page 85 HNS 3000 IO-Link page 37 octet bit offset 31 - 24 23 - 16 15 - 8 7 - 0 subindex element bit 7 - 0 7 - 0 15 - 8 7 - 0 Die Schaltbits BDCx sowie die physischen Schaltausgänge SPx sind intern miteinander gekoppelt.
  • Page 86 HNS 3000 IO-Link Variable "Primary Value SP2" index=65 id=V_PrimaryValueSp2 data type: 112-bit Record (subindex access not supported) access rights: rw modifies other variables data default subindex allowed values mod. other var. name description offset type value 0 = Normally 8-bit...
  • Page 87 HNS 3000 IO-Link page 39 octet 111 - bit offset 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 subindex element bit 7 - 0 7 - 0...
  • Page 88 HNS 3000 IO-Link Variable "SP States" index=72 id=V_SpStates data type: 8-bit Record (subindex access not supported) access rights: ro dynamic allowed mod. subindex data type default value name description offset values other var. Boolean false Primary Value SP1 Boolean false...
  • Page 89 HNS 3000 IO-Link page 41 Variable "Display Mapping" index=75 id=V_DspMapping data type: 8-bit UInteger allowed values: 0 = Primary Value, 1 = Secondary Value default value: 0 access rights: rw octet bit offset 7 - 0 element bit 7 - 0 Variable "Primary Value Display Unit"...
  • Page 90 HNS 3000 IO-Link Variable "Secondary Value Range" index=81 id=V_SecondaryValueRange data type: 72-bit Record (subindex access not supported) access rights: ro allowed default mod. subindex data type name description offset values value other var. 16-bit Integer -250 Lower Value 16-bit Integer...
  • Page 91 HNS 3000 IO-Link page 43 Variable "Secondary Value" index=85 id=V_SecondaryValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value Boolean...
  • Page 92 HNS 3000 IO-Link Variable "Secondary Minimum Value" index=89 id=V_SecondaryMinValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value Boolean false...
  • Page 93 HNS 3000 IO-Link page 45 Variable "Secondary Maximum Value" index=93 id=V_SecondaryMaxValue data type: 24-bit Record (subindex access not supported) access rights: ro dynamic allowed default mod. subindex data type name description offset values value other var. 16-bit Integer Process Value...
  • Page 94 HNS 3000 IO-Link Variable "BDC3 Behavior" index=16385 id=V_Bdc3Behavior data type: 32-bit Record (subindex access not supported) access rights: rw modifies other variables excluded from data storage allowed default subindex data type mod. other var. name description offset values value 0 = Default,...
  • Page 95 HNS 3000 IO-Link page 47 octet bit offset 31 - 24 23 - 16 15 - 8 7 - 0 subindex element bit 7 - 0 7 - 0 15 - 8 7 - 0 ErrorTypes Additional Code Name Description...
  • Page 96 HNS 3000 IO-Link Process Data Formatting Formatting for Process Data id=PI_PdIn Subindex 1: Subindex 2: Subindex 3: * 0.1 + 0 cm Dec.1 Subindex 4: Subindex 5: Subindex 6: * 0.1 + 0 °C Dec.1 Events Code Type Name Description...