ELTA FANS Jetflow SJ Series Installation And Maintenance Instructions

ELTA FANS Jetflow SJ Series Installation And Maintenance Instructions

Advertisement

Jetflow SJ
Installation and Maintenance Instructions
THESE INSTRUCTIONS MUST BE READ FULLY BEFORE
COMMENCING INSTALLATION
Code
SJ100
SJ100B
SJ125A
SJ125B
SJ150
SJ160
SJ200A
SJ200B
SJ250A
SJ315
SJ315B
SJ355A
SJ355B
Code
SJ100A
SJ100B
SJ125A
SJ125B
SJ150
SJ160
SJ200A
SJ200B
SJ250A
SJ315
SJ315B
SJ355A
SJ355B
Supply
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
230V/1Ph/50Hz
A
B
241
98
241
98
241
123
241
123
241
148
241
158
335
198
335
198
335
248
404
313
404
313
484
355
484
355
FL Amps
Input Watts
0.26
0.27
0.27
0.26
0.28
0.28
0.32
0.66
154
0.82
180
0.86
192
1.30
297
1.12
248
2.92
630
C
25
25
25
25
25
25
25
25
25
30
30
44
44
r/min
68
2000
60
2400
62
1700
58
2350
65
2350
63
2350
73
2400
2430
2450
2420
2630
1330
2560
D
Weight kg
210
3.0
210
3.0
210
3.5
210
3.5
210
3.5
210
3.5
230
4.5
230
4.5
230
5.5
295
6.0
308
7.0
400
11.8
400
14.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Jetflow SJ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ELTA FANS Jetflow SJ Series

  • Page 1 Jetflow SJ Installation and Maintenance Instructions THESE INSTRUCTIONS MUST BE READ FULLY BEFORE COMMENCING INSTALLATION Code Supply FL Amps Input Watts r/min SJ100 230V/1Ph/50Hz 0.26 2000 SJ100B 230V/1Ph/50Hz 0.27 2400 SJ125A 230V/1Ph/50Hz 0.27 1700 SJ125B 230V/1Ph/50Hz 0.26 2350 SJ150 230V/1Ph/50Hz 0.28 2350 SJ160...
  • Page 2 Upon receipt, the fan equipment should be visually inspected to check for any damage. Ensure that the impeller is free to rotate. If there are any queries concerning the fan equipment, Elta Fans Ltd should be contacted prior to the installation.
  • Page 3 Precaution must be taken to locate the exhaust discharge terminal so as to avoid the backflow of gases into the room from the open flue of gas or other fuel burning appliances. START-UP Before power is supplied to the unit, check that the wiring is correct as per the fan connection diagram.
  • Page 4 WIRING...
  • Page 5 GUARANTEE Elta Fans Ltd will, free of charge, within a period of 1 year from the date of despatch from their works, repair or at its option replace any goods which are proved to have defects as a result of defective materials or workmanship.

This manual is also suitable for:

Jetflow sj100Jetflow sj100aJetflow sj100bJetflow sj125aJetflow sj125bJetflow sj150 ... Show all

Table of Contents