Consider the possible positions of the indoor unit when positioning the outdoor unit. The piping and
cables of indoor and outdoor unit have to be connected.
G
ATTENTION
For SC 39xx models: The length of the pipe is 4 meter.
For S 39xx models: The maximum length of the piping between the indoor and outdoor unit is 15
Don't put animals and plants or other objects in front of the air inlet of air exhaust.
Always position the air conditioning at an easy to reach place.
Check and follow the local legislation and regulation regarding the positioning and installation of
air conditioning equipment.
If the unit is exposed to strong winds, for example when located by the sea, it has to be assured that
the fan is working properly by positioning the unit in the length direction along the wall or by using
dust or smoke deflectors. See Picture 6.
Strong
Picture 6
If the outdoor unit is installed on roofs of outer walls this can lead to disturbing noises and vibrations.
Make sure the outdoor unit can be secured on a firm foundation.
G
ATTENTION
If the outdoor unit is mounted against the wall, the bracket must comply with all technical
requirements. The wall has to be strong enough. Is this is not the case it needs to be reinforced.
The connections between support and wall and between support and air conditioning have to be
firm, solid and durable. In case of doubt, the unit can not be mounted and the necessary support
has to be calculated and constructed
by an authorised technician.
4
50
meters.
The maximum height difference between the indoor and outdoor unit is 5
meters.
Incorrect
wind
Correct
Barrier
Strong
wind