Variable-speed pumps
Table of Contents

Advertisement

Available languages

Available languages

Jandy
VS FloPro™ Variable-Speed Pumps
®
FILTER
HEATER
CHECK VALVE
(Check Valve recommended
for systems installed with Erosion Feeders
or salt chlorination systems)
SPA RETURN
Figure 2.
Typical Piping Installation
WARNING
A check valve can interfere with the proper
operation of certain Suction Vacuum Release
System (SVRS) products. To avoid possible entrap-
ment hazard, serious injury, or death, make sure
to review the operation/owners manual of your
particular SVRS product before installing the check
valve.
NOTE
When the pool equipment is located below the pool
surface a leak can result in large scale water loss or
flooding. Zodiac Pool Systems LLC cannot be responsible
for such water loss or flooding or damage caused by either
occurrence.
3.
Install the pump such that any disconnecting means
and/or junction boxes for power connection are within
sight of the pump and at least five (5) feet horizontally
from the edge of the pool and/or spa. Choose a
location that will minimize turns in the piping.
NOTE
In Canada, the minimum distance maintained from
the edge of the pool and/or spa as noted above must be
3 meters (10 feet), as required by the Canadian Electrical
Code (CEC, CSA C22.1).
4.
The pump should be installed on a firm, solid, and
level surface to avoid risk of settlement. Do not use
sand to level the pump as sand will wash away. Check
local building codes for any additional requirements
(Ex. Equipment pads in Florida must be concrete and
equipment must be secured to the pad.)
|
Installation & Operation Manual
PUMP
a.
POOL
RETURN
POOL/SPA
3 WAY VALVE
SKIMMER
a.
MANUAL BY-PASS DETAIL:
USE WHEN FILTRATION RATE
EXCEEDS 125 GPM FOR ZODIAC
HEATERS. REFER TO THE MANUFAC-
TURER'S RECOMMENDATIONS IF
USING A DIFFERENT BRAND HEATER.
NOTE
Zodiac Pool Systems LLC recommends bolting the pump
directly to the foundation.
5.
The pump foundation must have adequate drainage to
prevent the motor from getting wet. Protect the pump
from the rain and sun.
6.
Proper ventilation is required for the pump to operate
normally. All motors generate heat that must be
removed by providing proper ventilation.
In order to avoid premature failure or damage
to the pump motor, protect the pump from direct
water exposure from sprinklers, water runoff from
rooftops and drainage, etc.. Failure to comply may
cause pump failure, and may also void warranty.
7.
Provide access for future services by leaving a clear
area around the pump. Allow plenty of space above
the pump to remove the lid and basket for cleaning.
8.
If the equipment is in a potentially dark area,
provide adequate lighting.
Pipe Sizing
For assistance with suction and discharge pipe sizing,
please see Table 1.
Page 7
ENGLISH
SPA DRAIN
(Suction Outlet)
MANUAL BYPASS VALVE
CAUTION