Jandy VS FloPro VSFHP085AUT Installation And Operation Manual page 18

Variable-speed pumps
Table of Contents

Advertisement

Available languages

Available languages

Page 18
ENGLISH
Symptom
The pump gets hot and
shuts off periodically.
Pump will not start.
Variable-Speed Controller
LCD is not displaying
information
or
pump LEDs are not
illuminated.
Controller displays "Pump
not connected".
Fault message appears on
controller display.
Jandy
VS FloPro™ Variable-Speed Pumps
®
Make sure that there is adequate room around the motor to circulate air and keep the
motor cool. Have a qualified electrician check for loose connections and check the
voltage at the pump motor while it is in operation. The voltage must be within 10%
of the motor's data plate rating. If the voltage is not within 10%, contact a qualified
electrician and/or the local power service provider.
No power to pump.
Make sure pump is properly connected to high voltage. See Section 3.2, Electrical
Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address setting.
Make sure that pump DIP switches 3 and 4 are set properly for the installation. Both
should be OFF for use with Variable-Speed Controller or set to the proper address
when connected to an AquaLink
Z4™. See Section 3.3, Pump DIP Switch Settings, in this manual. Note: VS-FHP085
& VSFHP165JEP should always have DIP switch setting 5 set to ON for both
controllers.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how to
correct fault, contact Zodiac
Incorrect DIP switch setting.
Make sure pump DIP switches 1 and 2 are both ON if the controller is the JEP-R and
both are OFF if the controller is a PDA, AquaLink RS, or AquaLink Z4. See Section
3.3, Pump DIP Switch Settings, in this manual. Note: DIP Switch 5 should always be
in the ON position.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper low-voltage wiring.
Check low-voltage wiring between pump and controller. Correct if necessary. See
Section 3.2, Electrical Installation, in this manual.
Improper pump address set.
Ensure pump DIP switches 3 and 4 are set properly for the installation. Both should
be OFF for use with Variable-Speed Controller or set to the proper address when
connected to an AquaLink RS controller, an AquaLink PDA, or an AquaLink Z4. See
Section 3.3, Pump DIP Switch Settings, in this manual. Note: DIP Switch 5 should
always be in the ON regardless of the controller type.
Fault condition exists.
View fault message on controller and correct fault before proceeding. If unsure how
to correct fault, contact Zodiac Technical Support at 800.822.7933. In Canada, call
1-888-647-4004
|
Installation & Operation Manual
Possible Cause/Solution
RS controller, an AquaLink PDA, or an AquaLink
®
Technical Support at 800.822.7933.
®

Advertisement

Table of Contents
loading

Table of Contents