Adding Or Modifying A Blackhole Mac Address Entry; Adding Or Modifying A Multiport Unicast Mac Address Entry - H3C S12500X-AF Series Configuration Manual

Layer 2-lan switching
Hide thumbs Also See for S12500X-AF Series:
Table of Contents

Advertisement

Step
Add or modify a static or
3.
dynamic MAC address entry.

Adding or modifying a blackhole MAC address entry

Step
Enter system view.
1.
Add or modify a blackhole
2.
MAC address entry.

Adding or modifying a multiport unicast MAC address entry

You can configure a multiport unicast MAC address entry to associate a unicast destination MAC
address with multiple ports. The frame with a destination MAC address matching the entry is sent out
of multiple ports.
For example, in NLB unicast mode (see
All servers within a cluster uses the cluster's MAC address as their own address.
Frames destined for the cluster are forwarded to every server in the group.
In this case, you can configure a multiport unicast MAC address entry on the device connected to the
server group. Then, the device forwards the frame destined for the server group to every server
through all ports connected to the servers within the cluster.
Figure 3 NLB cluster
You can configure a multiport unicast MAC address entry globally or on an interface.
Command
interface-number
Enter Layer 2 aggregate
interface
interface
bridge-aggregation
interface-number
mac-address { dynamic | static }
mac-address vlan vlan-id
Command
system-view
mac-address
blackhole
mac-address vlan vlan-id
Figure
3):
23
Remarks
view:
By default, no MAC address entry
is configured on the interface.
Make sure you have created the
VLAN and assigned the interface
to the VLAN.
Remarks
N/A
By default, no blackhole MAC
address entry is configured.
Make sure you have created the
VLAN.

Hide quick links: