Locating Your Fireplace

E
A
Y
D
Y
F
Fig. 3 Locate gas fireplace.
A) Flat on wall
B) Cross corner
D) *Room divider
E) *Flat on wall corner
Y) 6" minimum
NOTE (Fig. 3):
** Island (C) and Room Divider (D) installation is possible as long as
the horizontal portion of the vent system (X) does not exceed 20' (6
m). See details in Venting Section.
* When you install your gas fireplace in (D) Room divider or (E) Flat
on wall corner positions (Y), a minimum of 6" (152 mm) clearance
must be maintained from the perpendicular wall and the front side
edge of the fireplace.

Clearance to Combustibles

Appliance
Top Standoffs ............................................0" (0 mm)
Bottom .......................................................0" (0 mm)
Side Standoffs ...........................................0" (0 mm)
Back Standoffs ..........................................0" (0 mm)
Front ....................................................36" (914 mm)
Top of Unit to Ceiling ...........................36" (914 mm)
Venting
Horizontal Termination through-a-side wall:
Vertical Sections:
Sides ..............................................2¹⁄₂" (64 mm)
Horizontal Sections:
Top .................................................3¹⁄₂" (89 mm)
Bottom ...........................................1¹⁄₂" (38 mm)
Sides ..............................................2¹⁄₂" (64 mm)
Vertical Vent Application:
Sides .............................................1¹⁄₂" (38 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 4a and 4b, the following Mantel Charts.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.
20011956
B
X
C
B
LU584-1
LU584-1
Locating unit
C) **Island
2/4/99 djt
F) Chase installation
A
B
C
D
E
Noncombustible Fin-
ish Material
(Such as Dura Rock)
Fireplace Front
CFM146c
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate Ref. of Comb. Chamber
Depth
V
10" (254 mm)
W
9" (229 mm)
X
8" (203 mm)
Y
7" (178 mm)
Z
6" (152 mm)
Fig. 4a Combustible mantel minimum installation.
Mantel
Leg
CFM164b
Side of Fireplace
CFM164b
Mantel Leg Char
DVT44
4/9/03 djt
Noncombustible
Finish Material
Mantel
Ref.
Leg Depth
CFM170
F
12" (305 mm)
DV Builder Front
G
9" (229 mm)
View
H
6" (152 mm)
I
4" (102 mm)
J
3" (76 mm)
Fig. 4b Combustible mantel leg minimum installation.
Chateau™
Combustible
Framing and Fin-
ish Wall Above
V
Standoffs
May use combus-
W
tible facing mate-
rial in this area
X
Standoff
Y
Z
Top of Sheet
Metal
Mantel from Top
CFM146c
DVT44
mantal chart
A
10" (254 mm)
B
9" (229 mm)
C
8" (203 mm)
D
7" (178 mm)
E
6" (152 mm)
J
I
H
G
F
K
L
M
N
O
CFM170a
Mantel Leg from Side
Ref.
of Comb. Opening
K
12" (305 mm)
L
9"
(229 mm)
M
6"
(152 mm)
N
4"
(102 mm)
O
3"
(76 mm)