DVRTSB Bay Window Fireplace

Glass Cleaning

It is necessary to periodically clean glass. During start-
up condensation, which is normal, forms on the inside
of the glass. This condensation causes lint, dust and
other airborne particles to cling to glass surface.
Also initial paint curing may deposit a slight film on the
glass. It is therefore recommended glass be cleaned
two or three times with a non-ammonia based house-
hold cleaner and warm water (We recommend gas
fireplace glass cleaner) within the first few weeks of
operation.
After the initial cleaning process the glass should be
cleaned two or three times during each operating
season depending on the environment in the house.
Clean the glass after the first two weeks of
operation.

Ceramic Refractory Installation

The rear wall refractory panels are installed in the unit
prior to shipment.
1. Unpack the ceramic refractory panels from their
carton.
Handle the refractory material carefully, the
panels are fragile.
2. Place the front floor refractory panels on the base
of the fireplace. (Fig. 38)
3. Place both side panels in place along the side of
the base. (Fig. 38)
Fig. 38 DVRTSB ceramic panels.
22
The logs can be identified by the number cast into
their underside.
The logs must be correctly placed in the order
described for the correct operation of the fireplace.
Refer to Figures 30 & 40 for log location and alignment.
1. Unpack the logs from the shipping carton. Handle
the logs carefully as they are fragile.
Handle and dispose of the plastic bags in a
safe manner. They are not toys and should
be kept away from infants.
2. Remove front glass/frame assembly.
3. Place the left rear (B105) and right rear (B106)
logs in place on the grate. The square hole in the
underside of the logs locates over the corner legs
of the grate. The inner ends of the log point to the
center of the burner.
4. Place the left front (B107) and right front (B108) logs
in place. Again the square holes fit over the corner
legs of the grate. The inner ends of these logs have
a recess in the underside which locates over knobs
on the top of the B105 and B106 logs to lock the
inner end in place.
5. Place the center front (B109) log in place. The notch
on the outer end of this log locates around the third
outer prong on the grate and the inner ends with a
round recess rest on lug on top of the left front log
(B107).
6. Place the center rear (B110) log in place. The square
hole in the underside of this log, locates over the
rear center bar of the grate. The inner end of the log
having a rectangular recess rests on the rectangular
knob on the end of the left front log, (B107).
B105
B107
FP1393
Fig. 39 DVRTSB logs.

Installation of Logs

B110
B108
B109
B106
LG298