Dutchwest Direct Vent / Natural Vent Gas Heater
Parallel Installation:
Minimum Clearance and Flue Centerline,
Direct Vent and Natural Vent
C
D
C L
B
Stove Clearances
A: 4" (102 mm)
B: 4" (102 mm)
Pipe Centerlines
C: 15¹⁄₂" (395 mm)
D: 9" (229 mm)
ST128b
Fig. 3 Parallel installation, minimum back and side clear-
Stardance
ances and flue centerlines.
flue centerline
Corner Installation:
9/28/00 djt
Minimum Clearance and Flue Centerline
Direct Vent and Natural Vent
B
B
A
Stove Clearance
A: 4" (102 mm)
Pipe Centerline
B: 14¹⁄₂" (370 mm)
Fig. 4 Corner installation, minimum corner clearances and
flue centerline.
6
C L
A
ST128c
A
ST129c
ST129c
Dutchwest
corner specs
5/15/03 djt
Wall Centerline from Floor
A
Effective Minimum
Wall Thimble
57¹⁄₂" (1461 mm) (CFM Pipe)
ST131c
Centerline
53¹⁄₂" (1359 mm) (Simpson DuraVent Pipe)
Dutchwest
Fig. 5 Minimum wall thimble centerline.
wall thimble
5/15/03 djt

Wall and Ceiling Clearances

B
C
A: Rear Wall
4" (102 mm)
B: Min. Clearance
45¹⁄₂" (1156 mm)*
C: Min. Alcove Height
73¹⁄₂" (1867 mm)*
ST101c
D: Max. Alcove Depth
48" (1220 mm)
Dutchwest
Direct Vent
Sidewall Clearance
4" (102 mm)
Min. Clrnc
* needed for installing DuraVent Minimum Vent Kit #2792 or CFM Corpora-
5/15/03 djt
tion Minimum Vent Kit #7TFSDVSK.
Fig. 6 Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Dutchwest Heater must be installed on rigid floor-
ing. When the heater is installed directly on any com-
bustible surface other than wood flooring, a metal or
wood panel extending the full width and depth of the
unit must be used as the hearth. There are no other
hearth requirements.
ST131c
A
D
A
ST101c
30001935