Thermostat Connection (optional)

Use only a thermostat rated for 500 millivolts.
Check the table below for the appropriate gauge ther-
mostat wire to use for the length of lead required in your
installation.
Thermostat
Wire / Gauge
18
16
14
1. Install the wall thermostat in the desired location and
run the wires to the stove location. Terminate these
leads with 1/4" female connectors.
2. Connect the thermostat wires to the valve. (Fig. 42)
Install the Stove Front
Insert the handle stub into the hole in the front casting.
Fasten in place witht he 3/8" locking nut provided. (Fig.
43)
The front attaches to the stove by four steel tabs that
engage with corresponding cast ribs onto the sides
and bottom of the stove body. Position the front about
3" down from stove top and lift the plate to engage the
upper tabs behind the adjacent ribs on the sides. (Fig.
44) Then lower the front into position, so the lower tabs
engage with the corresponding ribs at the bottom.
When properly installed, the bottom of the stove front
cannot be pulled away from the sides without also lifting
it.
22
Maximum Run
20 feet
20 - 40 feet
up to 60 feet
3/8" Locking
Nut
ST773
Fig. 43 Insert handle stub into hole in front. Secure with 3/8"
locking nut.
Engage steel tabs behind
the cast iron bosses
ST771
Fig. 44 Install the front plate.
ST771
DW
stove front
5/30/03 djt
Handle Stub
ST773
handle assy
6/6/03
Bottom tabs engage
notch in the leg