Advertisement

Quick Links

THE C60 SERIES
A line interactive uninterruptible power
supply (UPS) solution available from 800VA –
2000VA.
www.certaups.com
C60 USER MANUAL
For assistance please contact your local
A COMPLETE INSTALLATION
CertaUPS partner.
AND USER GUIDE

Advertisement

Table of Contents
loading

Summary of Contents for CertaUPS C60 Series

  • Page 1 THE C60 SERIES A line interactive uninterruptible power supply (UPS) solution available from 800VA – 2000VA. www.certaups.com C60 USER MANUAL For assistance please contact your local A COMPLETE INSTALLATION CertaUPS partner. AND USER GUIDE...
  • Page 2: Table Of Contents

    UPS INSTALLATION ..........................8 UNPACKING ............................8 C60 BOX CONTENTS CHECKLIST ......................9 C60 SERIES STARTUP AND SHUTDOWN ....................10 STARTING THE UPS WITH MAIN POWER PRESENT ................10 STARTING THE UPS FROM BATTERY ....................10 UPS SHUTDOWN WITH MAINS POWER .................... 11 UPS SHUTDOWN WITHOUT MAINS POWER ..................
  • Page 3: Safety Information

    Not to be disposed of in general waste Waste electrical equipment or electronic equipment (WEEE) should not be disposed of in the general waste. CertaUPS systems should always be disposed of at a proper recycling/hazardous waste disposal centre. Please see page 10 for disposal guidance.
  • Page 4: Operating Safety

    CAUTIONARY NOTES Please be aware of the following risks when handling and operating CertaUPS units. RISK TYPE DETAILS Even after the unit is disconnected from the mains power supply (building outlet socket), components inside the UPS are still energised which are potentially dangerous.
  • Page 5: The Model List

    FULL PRODUCT DETAILS CAN BE FOUND AT WWW.CERTAUPS.COM/PRODUCT/CERTAUPS-C60/ The CertaUPS C60 series is a line-interactive uninterruptible power supply (UPS) solution. It is one of the most compact systems available, providing the safe shutdown of supported equipment in the event of a power failure.
  • Page 6: Ups Standards

    INSPECTION Every effort is made to ensure that CertaUPS systems are packaged as safely as possible to ensure that no damage is incurred during shipment. Please visually inspect the UPS when it is received. Please keep all packaging in a safe place for future use.
  • Page 7: C60 Box Contents Checklist

    C60 BOX CONTENTS CHECKLIST C60 Series UPS USB A to B Software CD Power lead Warranty Card Quick start guide IF ANY OF THE ITEMS ARE MISSING FROM THE UPS BOX PLEASE NOTIFY YOUR SUPPLIER DO NOT FORGET TO REGISTER THE UPS WARRANTY WWW.CERTAUPS.COM/SUPPORT/WARRANTY-REGISTRATION/...
  • Page 8: C60 Series Startup And Shutdown

    Press power switch on the front panel of the UPS to turn on the UPS. Press switch again to turn off the UPS. C60 SERIES STARTUP AND SHUTDOWN STARTING THE UPS WITH MAIN POWER PRESENT Please switch off the connected loads before turning on the UPS, and switch on connected devices one by one after the UPS is turned on.
  • Page 9: Ups Shutdown With Mains Power

    To start the UPS via battery power (Cold start): Check all the connections are properly connected and correct. Press the button and the UPS will power on. The fans will start and the LCD will show the default UPS status summary screen after finishing the initialisation self-test. After a few seconds, the UPS will transfer to battery mode.
  • Page 10: C60 Series Operation

    C60 SERIES OPERATION LCD PANNEL The CertaUPS C60 has a graphical LCD screen. It provides useful information about the UPS itself, load status, events, measurements and settings. Input voltage Output voltage AC mode indicator Battery mode indicator Load level indicator, flashing indicates overload...
  • Page 11: Ups Maintenace

    FOR FURTHER GUIDANCE ON UPS MONITORING, PLEASE CONTACT YOUR CertaUPS PROVIDER OR VISIT WWW.CERTAUPS.COM UPS MAINTENACE ADOPTING A PREVENTATIVE MAINTENANCE SCHEDULE IS CRITICAL TO ACHIEVING OPTIMUM UPS PERFORMANCE UPS CARE For the best preventive maintenance: Keep the area around the equipment clean...
  • Page 12: Storing The Ups

    Ensure the batteries are recharged every six months for a minimum of 48 hours Ensure EBMs are recharged every six months for a minimum of 3 hours TROUBLESHOOTING The C60 series is designed for durable, automatic operation. TO REGISTER A FAULT PLEASE VISIT WWW.CERTAUPS.COM/SUPPORT/FAULT-REPORTING/ Use the following troubleshooting chart to determine the UPS alarm condition.
  • Page 13: Technical Data

    TECHNICAL DATA ELECTRICAL SPECIFICATION INPUT MODEL C60-800 C60-1000 C60-1500 C60-2000 CAPACITY 800VA/480W 1000VA/600W 1500VA/900W 2000VA/1200W Input Voltage 220/230/240VAC Voltage Range 162-290VAC OUTPUT Voltage Regulation +/-10% Transfer Time Typical 2-6ms, 10ms max. Waveform Simulated Sinewave BATTERY Type & Number 12V/9Ah x 1 12V/7Ah x 2 12V/9Ah x 2 12V/9Ah x 2...
  • Page 14: Runtimes

    146 x 397 x 205 11.1 C60-2000 146 x 397 x 205 11.5 A FULL GLOSSARY OF TERMS CAN BE FOUND AT: WWW.CERTAUPS.COM/SUPPORT/UPS-GLOSSARY/ FOR FURTHER INFORMATION OR ASSISTANCE, PLEASE CONTACT YOUR CertaUPS REPRESENTATIVE OR VISIT: WWW.CERTAUPS.COM 16 | P a g e...

This manual is also suitable for:

C60-800C60-1000C60-1500C60-2000

Table of Contents