5a) Technical specifi cations of the amplifi er
Power supply
Standby consumption
Active audio consumption 550 mA
Audio power in the apartment-outdoor panel direction
Audio power in the outdoor panel-apartment direction
Operating temperature
Volume adjustable in both directions
6a) Outdoor panel amplifi er parameters
Lock release activation time
Exit button activation time
Maximum conversation time
Type of outdoor panel
Block Number
Sub-Block Number
Outdoor Panel Number
Door sensor time
Volume monitoring
Non-active MASTER outdoor panel
Mapping
Sequential programming time of pushbuttons following halt of activity
Inverse programming time of pushbuttons following halt of activity
b) CONFIGURATION
The DUOX amplifi er includes "Restore" and "Change Value" functions which enable users to restore/
change the parameters that have been programmed.
1b) Reset of the mapping of the call code of the pushbuttons
In order to reset the mapping that has been created:
- Remove the power supply.
- Press the SW1 programming button to supply power to the amplifi er and hold this button down until
the "beep-beep" confi rmation signal is heard (5 seconds).
Note: This mapping reset function is for all of the outdoor panels with PUSHBUTTONS regardless of the aesthetic
design:
- Cityline outdoor panels
- Marine outdoor panels
- Skyline outdoor panels
40
18 Vdc
94mA
1 W
0,15 W
[-10º , +60ºC] / [-14º, 140ºF]
01...99 sec. (by default: 03)
00...99 sec. (by default: 06) / (deactivated: 00)
90 sec.
sub-block/block/general entrance. (by default: block)
00..99, (by default: 00)
00..99, (by default: 00)
0..9, (by default: 0)
000..250, (by default: 000, non-active)
0..9, (by default: 5)
60 sec.
300 sec.