GRUNDFOS INSTRUCTIONS
G 401, G 402, G 403,
G 404, G 405, G 406
Installation and operating instructions

Advertisement

Table of Contents
loading

Summary of Contents for Grundfos G 401

  • Page 1 GRUNDFOS INSTRUCTIONS G 401, G 402, G 403, G 404, G 405, G 406 Installation and operating instructions...
  • Page 2 G 401, G 402, G 403, G 404, G 405 and G 406, to which this declaration G 401, G 402, G 403, G 404, G 405 und G 406, auf die sich diese Erklä- relates, are in conformity with the Council Directives on the approxima-...
  • Page 3 Мы, фирма Grundfos, со всей ответственностью заявляем, что nyilatkozat vonatkozik, megfelelnek az Európai Unió tagállamainak jogi изделия G 401, G 402, G 403, G 404, G 405 и G 406, к которым и irányelveit összehangoló tanács alábbi irányelveinek: относится данное свидетельство, отвечают требованиям...
  • Page 5 G 401, G 402, G 403, G 404, G 405, G 406 Installation and operating instructions Montage- und Betriebsanleitung Notice d’installation et d’entretien Istruzioni di installazione e funzionamento Instrucciones de instalación y funcionamiento Instruções de instalação e funcionamento Οδηγίες εγκατάστασης και λειτουργίας...
  • Page 6: Table Of Contents

    General description GSM modem via Ethernet Applications G 401 and G 402 The G 401 and G 402 are connected to a CU 401 G 403 control unit via an Ethernet cable. See cable specifi- G 404 and G 405 cation in section 12.
  • Page 7: G 400 Module

    3. G 400 module Pos. Description Function Indicator lights Status indication GSM/GPRS antenna connection Connection of external antenna GENIbus connection Connection of other GENIbus products USB plug Updating of software in the G 400 Switching off the internal battery during transporta- Switch for internal back-up battery tion and when updating of the G 400 Connection of power supply (PU 101)
  • Page 8: Mounting

    4. Mounting The G 400 module must be mounted on a 35 mm standard DIN rail (EN 50022). Recommended height 7.5 mm. Min. 20 mm The size of the module appears in section 15. Dimensions. All dimensions are in mm. Min.
  • Page 9: Indicator Lights (Leds)

    5. Indicator lights (LEDs) On System fault Off No fault On In operation Off Out of operation On Supply connected Off Supply not connected Capacity of internal back-up battery Capacity of internal back-up battery too small for GSM transmission On G 400 connected to GSM operator G 400 not connected to GSM operator On Modem sending...
  • Page 10: Ethernet

    6. Ethernet If the G 400 is connected to a network hub or net- work switch, a standard cable must be used. Applies to: • G 401 Standard cable • G 402 To G 400 To hub or switch • G 403 •...
  • Page 11: Updating Of Firmware

    Note: It is advisable to use an SMA-M 90°-angle ing the switch to the right, see fig. 2. plug. Grundfos offers an antenna which can be used Switch on the power supply. for the whole G 400 range of modules, product The G 400 now collects the update from the number: 96095287.
  • Page 12 8.6.1 Inserting the SIM card Do not insert/replace the SIM card unless the G 400 is dead. Note: The internal back-up battery must also be switched off. Step Illustration Action Switch off the normal power supply and the UPS by removing the terminals to "+, –, 1, 2, 3".
  • Page 13 Insert the SIM card in the drawer. Note: The SIM card must lie correctly in the drawer. Insert the drawer with the SIM card. Note: Check that the drawer engages correctly with the guide rails of the G 400 module. Gently push the drawer into place.
  • Page 14: Rs-232 Port

    • G 406. radio modem. The GENIbus enables the connection of other To be connected to the RS-232 port with one of the Grundfos E-products for wireless communication. cables supplied: 11. Connection • DCD cable: - RJ45 for 9-pin D-SUB plug.
  • Page 15: Technical Data

    12. Technical data Applies to: • G 401 • G 402 • G 403 • G 404 • G 405 • G 406. Supply voltage 24 VDC ±7%. Current consumption • Max. 10.8 W. • 24 V ~ 450 mA.
  • Page 16: Replacement Of G 400

    13. Replacement of G 400 • Switch off the power supply to the G 400. • Turn the locking screw to "slide position". Use a 6 mm screwdriver for slotted screws. Slide position • Remove the terminals, the antenna and Ethernet cables and turn the locking screw to position "unlocked".
  • Page 17: Maintenance

    14. Maintenance The internal back-up battery gets worn and must be replaced when the indicator light "B" goes out and does not light up after 2 hours' charging. The battery is available as a service kit. 15. Dimensions 16. Disposal This product or parts of it must be disposed of in an environmentally sound way: Use the public or private waste collection...
  • Page 18 Block diagram...
  • Page 22 Service in Deutschland: Telefax: +60-3-5569 2866 GRUNDFOS Pumpen AG Tel.: +43-6246-883-0 e-mail: kundendienst@grundfos.de Bruggacherstrasse 10 Mexico Telefax: +43-6246-883-30 Bombas GRUNDFOS de Mexico S.A. CH-8117 Fällanden/ZH Greece GRUNDFOS Hellas A.E.B.E. de C.V. Tel.: +41-1-806 8111 Belgium N.V. GRUNDFOS Bellux S.A. 20th km. Athinon-Markopoulou Av.
  • Page 23 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96095264 0406 Repl. 96095264 1105 www.grundfos.com...