NOTE ON REPAIR WORK SAFETY

Follow the instructions below, both to prevent accidents when making repairs and to ensure post-repair
product safety.
Do not apply voltages other than those specified for the equipment or its compo-
nents.
Applying voltages other than the rated voltage could cause electrical breakdown or over-current, possi-
bly resulting in electric shock or fire.
Do not modify the design of circuit boards or other electronic elements.
Modifying circuit boards could cause electric shock or result in a fire hazard due to excessive heat
build-up. User modification automatically exempts the manufacturer from all personal and property lia-
bility caused by such modification, and the user who carried out such modification shall be solely
responsible for such accidents.
• About lead-free solders
Since lead can become an environmental contaminant, this unit has been manufactured using solders
that contain no lead in the printed circuit board.
[While conventional solders are alloys of zinc and lead, lead-free solder is comprisend of an alterna-
tive alloy that contains no lead.]
NOTES
• Circuit boards using lead-free solder bear a lead-free solder designation. To maintain the integrity
of this designation, be sure to use lead-free solder when repairing such lead-free solder circuit
boards. Boards not marked with the lead-free solder designation may legally be serviced using
conventional solders.
• Because the melting point of lead-free solder (approximately 220°C) is 30°C-40°C higher than that
of conventional (lead-zinc alloy) solder, it tasks little longer to melt. It is recommended that a sol-
dering iron with controllable temperature be used and set to 20°C higher than would normally be
used with conventional solder.
Identifying printed circuit boards that use free-lead solder
Printed circuit boards that use lead-free solder have the following designation printed or stamped on
either side of the board.
2
NOTE ON REPAIR WORK SAFETY

GENERAL DESCRIPTION

The IR-200M (hand-held type) and IR-300M (hands-free type) infrared wireless microphones are
intended for speech applications and use unidirectional electret condenser microphone units featuring
high sensitivity and clear sound.
GENERAL DESCRIPTION
IR-200M, IR-300M Y
2