Quick Links

IP REMOTE MICROPHONE STATION
Thank you for purchasing TOA's IP Remote Microphone Station.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.

TABLE OF CONTENTS

1. SAFETY PRECAUTIONS ............................. 1
2. GENERAL DESCRIPTION ........................... 1
3. FEATURES ................................................... 1
4. INSTALLATION ............................................ 2
4.1. Desk-Top Installation ............................... 2
4.2. Wall Hanging .......................................... 3

1. SAFETY PRECAUTIONS

• Before installation or use, be sure to carefully read all the instructions in this section for correct and safe
operation.
• Be sure to follow all the precautionary instructions in this section, which contain important warnings and/or
cautions regarding safety.
• After reading, keep this manual handy for future reference.
CAUTION
• Use the specified AC adapter for the unit. Note that the use of other adapter may cause a fire.

2. GENERAL DESCRIPTION

The N-8610RM IP Remote Microphone Station is designed for use with TOA's packet intercom system (IP
network compatible intercom system) that employs the packet audio technology*.
Connecting the N-8610RM to a LAN or WAN permits conversations between IP stations and paging. Using the
N-8610RM in combination with the SX-200IP IP Interface Module permits announcements to be made to the
SX-2000 Matrix System.
* Technology related to audio transmission over a network.

3. FEATURES

• Can be connected to an existing local area network (LAN) or wide-area network (WAN). The system can also
be easily connected to fiber-optic networks without restrictions on operating distance.
• The dedicated N-8000 software program enables centralized control with a personal computer.
• System maintenance (verifying operation log and line supervision) can also be performed with a PC and
Internet browser.
• Connecting the station to a PoE (Power over Ethernet) switching hub eliminates the need for an AC adapter.
• Connecting an optional RM-210 Remote Microphone Extension expands the number of function keys and
indicators in 10 units. Up to 4 RM-210s can be connected when an AC adapter is used, and up to 2 RM-210s
in the case of PoE power supply.
• Using an optional WB-RM200 Wall-Mounting Bracket, the station can be mounted on a wall.
PRODUCTS .................................................. 8
5.1. Accessories ............................................ 8
5.2. Optional Products ................................... 8
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
INSTALLATION MANUAL
N-8610RM
Name Labels .......................................... 5
133-21-00001-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the N-8610RM and is the answer not in the manual?

Questions and answers

Summary of Contents for Toa N-8610RM

  • Page 1 • Use the specified AC adapter for the unit. Note that the use of other adapter may cause a fire. 2. GENERAL DESCRIPTION The N-8610RM IP Remote Microphone Station is designed for use with TOA's packet intercom system (IP network compatible intercom system) that employs the packet audio technology*. Connecting the N-8610RM to a LAN or WAN permits conversations between IP stations and paging. Using the N-8610RM in combination with the SX-200IP IP Interface Module permits announcements to be made to the SX-2000 Matrix System.
  • Page 2 4.1.1. N-8610RM expansion with the addition of the RM-210 When adding an RM-210 Remote Microphone Extension to expand the N-8610M, use the RM-210's Extension cable and included Linkage Bracket to link the 2 units. Follow the procedures below. Step 1. Turn over both the N-8610RM and the RM-210, and keep them in close contact with each other. Step 2. Connect between the RM-210 connection terminal (EXTENSION) on the N-8610RM side and the RM connection terminal (EXTENSION) on the RM-210 side using the extension cable supplied with the RM-210. In this case, install the ferrite clamp...
  • Page 3 Unit: mm • Be sure to use 2 screws when mounting the bracket to the wall. Step 2. Hook the bottom surface of the N-8610RM onto the WB-RM200. Step 3. Plug the LAN cable into the N-8610RM's LAN terminal. LAN cable In this case, install the ferrite clamp supplied with the N-8610RM on the LAN cable as shown below.
  • Page 4 4.2.2. RM-210 The RM-210 can be mounted on a wall using an optional WB-RM200 Wall-Mounting Bracket. Step 1. Install the N-8610RM to the wall. (Refer to the previous page.) Step 2. Install the WB-RM200 used for mounting the RM-210 to the wall. Step 3. Connect between the RM-210 connection terminal (EXTENSION) on the N-8610RM side and the RM Extension cable...
  • Page 5 4.3. Creating Remote Microphone Name Labels 4.3.1. Creating name labels using the SX-2000 Setting Software Using the SX-2000 Setting Software function, assigned names of preset N-8610RM and RM-210 Function keys can be printed out. Once printed, cut out the printed names with scissors to use them as corresponding name labels. The paper used for the name label must be under 0.2 mm in thickness.
  • Page 6 4.3.3. If the name label is not printed correctly The name label created using the SX-2000 Setting Software may not be printed in correct size depending on the configuration environment of your PC. In such cases, try one of the methods described below. (1) Preparation by hand Copy the [Dimensional diagram for printing devices] shown below to a paper with under 0.2 mm in thickness. After writing names, cut out the pattern paper aligning it with the cutting guidelines.
  • Page 7 * U se the AC adapter AD-1215P (optional) or the T/100BASE-TX in auto-sensing. equivalent. Connecting the station to a PoE (Power over As for the usable adapter, consult your TOA Ethernet) switching hub compliant with IEEE802.3af dealer. eliminates the need for an AC adapter. (For connection, refer to the instruction manual supplied Note with the switching hub.)
  • Page 8 AC adapter: AD-1210P* , AD-1215P* Remote microphone extension: RM-210 Wall mounting bracket: WB-RM200 Consult your TOA dealer when using an equivalent adapter. Version update information • Download our TOA Products Data, web site (http://www.toa-products.com/international/) to get the up-to- date version for N-8000 setting software, firmware, and Instruction manuals. • The software version number can be confirmed using the Help menu. • The current firmware version can be confirmed on the system management screen displayed when the browser establishes the connection to the station.

Table of Contents