5. Options of the thermostat (cont.)
PAr2
Program # and RESET.
PAr3
Room temperature correction. Allows you
to correct the room temperature display
(for value -5 ° C to + 5 ° C).
PAr4
Hysteresis.This parameter specifies the
number of degrees C by which the
temperature in the room below the preset
temperature must fall in order for the
thermostat to switch on the relay.
OFF
Turning off thermostat operation.
6. First start
1. When the batteries are in, the display will show
0:00 hours, and the thermostat will work in P1
mode - see point 7 "PROG mode - program-
ming the automatic operation mode".
2. Use the "-/+" buttons to set the actual hour.
Confirm by pressing
please follow the same procedure. Confirm by
pressing
t
day of the week will be shown.
3. Use the "-/+" buttons to set the actual day of the
week. Confirm by pressing
will show the main screen, taking into account
the introduced settings. The controller is in the
P1 program - see point 7 "PROG mode -
programming the automatic operation
mode", using the default settings of the
comfort temperature (day) at the level of 21°C
and the lowered temperature (night) at the level
of 18°C. The way of changing the default
tempe-ratures has been described in the point
15 "Setting the default day and night tempe-
rature".
6
Room thermostat DK LOGIC 100
; To set minutes,
t
. A screen showing the current
. The controller
AUTO
AUTO