Vetter SmartFork Operating Instructions Manual page 22

Flash control device
Hide thumbs Also See for SmartFork:
Table of Contents

Advertisement

Technical data
SmartFork® Flash: Driver V2.0 data
Key data
n
Control of the SmartFork
n
2 independent channels (not more than 60 LEDs per channel)
n
Function selection via integrated switches
Can be configured via USB
n
n
1x analogue input 0 – 10 V for insertion depth display
n
1x digital input (max. 24 V)
Electrical data
n
Operating voltage 12 – 24 V/DC
n
Power consumption, max.: 24 W
Plug connec-
tions
1
2
3
4
5
1
2
3
4
5
6
7
8
22
®
Digital input
Analogue input (0 – 10 V)
12 – 24 V
GND
Bypass to X2 pin 8
5 V
12 V
Data 1
Clk 1
Data 2
Clk 2
GND
Bypass to X1 pin 5
®
SmartFork
Flash LED bands
X1
M12 8-pin plug A-coded
X2
M12 8-pin socket A-coded
LED band 1
LED band 2
Flash control device
V.09/2019