ELAN HOME SYSTEMS
Even when VIA!NET Repeaters are utilized, the combined
TOTAL LENGTH of wire runs in each "sub-net" still
MUST NOT EXCEED 1000 feet.
NOTE: Use of system-specific Precision Panels for S and VIA!
is required for proper functionality when integrating serial con-
trolled devices with the SC-1.
VIA!NET Repeaters
VIA!NET Repeaters allow devices to be installed at distances that
are in excess of normal maximum wire run lengths. Punch the re-
peater down on a PVIA or other VIA!NET Precision Panel as shown
in the drawing below.
Keep in mind the following points:
• Use VIA!NET Repeaters when the TOTAL combined wire
length to all VIA! Touch Panels or SC-1 VIA!NET Ports exceeds
the 2000 ft. maximum limit.
NOTE: Wire runs WITH VIA!NET Repeaters still must not exceed
1000ft. in length.
As many as 30 wire runs WITH VIA!NET Repeaters may
be utilized, as long as NONE of the individual runs exceed
1000 ft. in length.
The combined length of all wire runs remaining
WITHOUT VIA!NET Repeaters ('sub-net') must not exceed
1000 ft.
© ELAN Home Systems 2008 • All rights reserved
SC-1 INSTALLATION MANUAL
Page 15