8.7

UV contrast medium filling

i
By default, individual service phases are linked to
other service phases as they are needed to fully per-
form the individual operation selected.
i
The vehicle air conditioning system is partly filled
with UV contrast medium to facilitate detection of
leaks in the event of damage to the vehicle air condi-
tioning system.
M2
EVHP1
EVHP2
T2
M1
T1
EVLP1
EVLP2
R2
R1
HOSE FLUSH MANIFOLD
P2
HP
F2
6
C
Name
Description
1
Fresh oil tank
2
Vacuum pump
3
Expansion valve
4
Evaporator/oil separator
5
Compressor oil separator
6
Compressor
7
Internal refrigerant cylinder
8
Refrigerant cylinder scales
9
Used oil bottle
10
Heat exchanger
11
UV dye bottle
12
Fresh oil scales
13
Used oil scales
EV1
Vacuum solenoid valve
EV3
Flow solenoid valve
EV5
Recovery solenoid valve
EV6
Filling solenoid valve
Robert Bosch GmbH
EV10
P1
EV9
VU3
11
3
SERVICE PORT
VU2
5
4
10
EV7
9
13
Name
Description
EV7
Oil drain solenoid valve
EV8
Oil injection solenoid valve
EV9
Contrast medium injection sole-
noid valve
EV10
Solenoid valve for separating
high and low pressure
EVHP1 High pressure solenoid valve
EVHP2 High pressure solenoid valve
EVLP1
Low pressure solenoid valve
EVLP2
Low pressure solenoid valve
F1
Coarse filter
F2
Combi filter
HP
High pressure
LP
LOw pressure
M1
Low pressure gage
M2
High pressure gage
M3
Internal refrigerant cylinder pres-
sure gage
Service phases | ACS 652 | 19
i
If "UV contrast medium filling" has been selected in
the service process, a defined quantity (time con-
trolled) entered is fed into the vehicle air condition-
ing system along with the refrigerant.
i
EVHP1, EVHP2 and EV9 opens and the UV contrast
medium (11) is fed into the vehicle air conditioning
system with the refrigerant.
EV3
EV5
EV8
EV1
2
VU1
P
1
12
F1
V5
V6
V1
V3
7
8
Name
P1
P2
R1
R2
T1
T2
V1
V2
V3
V4
V5
V6
VU1
VU2
VU3
EV6
M3
V4
V2
Description
Pressure sensor
Pressure switch
Low pressure flushing connection
High pressure flushing connection
Low pressure hose
High pressure hose
Tank vapour side hose valve
Tank liquid side hose valve
Tank vapour side valve
Tank liquid side valve
Safety valve
Non condensable drain valve
Oil non-return valve
One-way valve
UV contrast medium non-return
valve
|
1 689 975 257
2019-05-15
en