Separating And Returning Compressor Oil - Bosch ACS 652 Repair Instruction

A/c service unit
Table of Contents

Advertisement

8.9
Separating and returning compressor
oil
i
During the recovery phase and preparation of the
refrigerant, small quantities of compressor oil get
into the internal circuit.
M2
EVHP1
EVHP2
T2
M1
T1
EVLP1
EVLP2
R2
R1
HOSE FLUSH MANIFOLD
F2
6
C
Name
Description
1
Fresh oil tank
2
Vacuum pump
3
Expansion valve
4
Evaporator/oil separator
5
Compressor oil separator
6
Compressor
7
Internal refrigerant cylinder
8
Refrigerant cylinder scales
9
Used oil bottle
10
Heat exchanger
11
UV dye bottle
12
Fresh oil scales
13
Used oil scales
EV1
Vacuum solenoid valve
EV3
Flow solenoid valve
EV5
Recovery solenoid valve
EV6
Filling solenoid valve
Robert Bosch GmbH
EV10
P1
VU3
11
P2
HP
VU2
5
4
EV7
9
13
Name
Description
EV7
Oil drain solenoid valve
EV8
Oil injection solenoid valve
EV9
Contrast medium injection sole-
noid valve
EV10
Solenoid valve for separating
high and low pressure
EVHP1 High pressure solenoid valve
EVHP2 High pressure solenoid valve
EVLP1
Low pressure solenoid valve
EVLP2
Low pressure solenoid valve
F1
Coarse filter
F2
Combi filter
HP
High pressure
LP
LOw pressure
M1
Low pressure gage
M2
High pressure gage
M3
Internal refrigerant cylinder pres-
sure gage
Service phases | ACS 652 | 21
i
This oil is separated from the refrigerant in the com-
pressor oil separator (5) and is then fed back to the
compressor (6).
EV9
EV8
EV1
VU1
1
12
3
F1
SERVICE PORT
V1
10
EV3
EV5
2
P
V5
V6
V3
V4
V2
7
8
Name
Description
P1
Pressure sensor
P2
Pressure switch
R1
Low pressure flushing connection
R2
High pressure flushing connection
T1
Low pressure hose
T2
High pressure hose
V1
Tank vapour side hose valve
V2
Tank liquid side hose valve
V3
Tank vapour side valve
V4
Tank liquid side valve
V5
Safety valve
V6
Non condensable drain valve
VU1
Oil non-return valve
VU2
One-way valve
VU3
UV contrast medium non-return
valve
|
1 689 975 257
en
EV6
M3
2019-05-15

Advertisement

Table of Contents
loading