DLP-G675 Verify the ONS 15454 M6 Shelf for DC Power Module Installation
Figure 27: AC Power Module Installation Rear Side of the ONS 15454 M6 Shelf
Step 2
Loosen the screw and move it to the left position (towards the AC silk-screen text).
Step 3
Tighten the screw again to a torque value of 4 in-lb (0.45 N-m).
DLP-G675 Verify the ONS 15454 M6 Shelf for DC Power Module Installation
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Procedure
Step 1
Verify the position of the mechanical locking system on the rear side of the chassis. To use the DC power
module the screw must be close to the DC silk-screen text (see the following figure).
Installing the ONS 15454 M6 Shelf
28
This task verifies the shelf for DC power module installation.
None
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves