Cisco ONS 15454 M6 Installation Manual page 132

Hide thumbs Also See for ONS 15454 M6:
Table of Contents

Advertisement

DLP-G295 Install Alarm Wires in ONS 15454 M6
Pin Number
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Installing the ONS 15454 M6 Shelf
132
Color Code
Input Alarms - Right Alarm Connector
Black/Red
Input Pair #2 +
Black/Yellow
Input Pair #4 +
Black/Green
Input Pair #5 +
Black/Blue
Input Pair #6 +
White/Blue
White/Orange
Input Pair #8 +
White/Green
Input Pair #9 +
White/Brown
Input Pair #10 +
Brown/Black
Input Pair #1 -
Red/Black
Input Pair #2 -
Yellow/Black
Input Pair #4 -
Green/Black
Input Pair #5 -
Blue/Black
Input Pair #6 -
Orange/White
Input Pair #8 -
Green/White
Input Pair #9 -
Brown/White
Input Pair #10 -
Installing the ONS 15454 M6 Shelf
Input-Output Alarms - Left Connector
Major Audible Alarm +
Remote Audible Alarm +
Minor Visual Alarm +
Major Visual Alarm +
Remote Visual Alarm +
Alarm Cutoff (ACO) +
Minor Audible Alarm -
Major Audible Alarm -
Remote Audible Alarm -
Minor Visual Alarm -
Major Visual Alarm -
Remote Visual Alarm -
Alarm Cutoff (ACO) -

Advertisement

Table of Contents
loading

Table of Contents