12-7.
T/C Recovery Mode
The machine enters the T/C recover mode when a T/C of 10 % or less is detected.
Toner is replenished for 90 sec.
T/C is recovered by 1 % or more.
Toner is replenished for 60 sec.
T/C is recovered by 2 % or more, or is 12 % or more.
Toner is replenished for 30 sec. to complete the
T/C recovery mode.
A toner-empty condition is reset when the Front Cover is opened and closed after a T/C
of 10 % or more is detected with the supply of toner replenished.
A toner-empty-stop condition is reset when the Front Cover is opened and closed after a
T/C of 8 % or more is detected with the supply of toner replenished. A toner-empty condi-
tion results, however, if T/C falls within the range between 8 % and 10 % when the Front
Cover is opened and closed.
T/C is not recovered by 1 % or more, or T/C
is less than 12 %.
A toner-empty condition is detected.
A toner-empty-stop condition results and the initiation
of any new copy cycle is prohibited.
M-26
T/C is not recovered by 2 % or
more, or T/C is less than 12 %.
T/C is less than 8 %.