Brinkmann SFC1520 Series Operating Instructions Manual page 3

Cutter pumps
Table of Contents

Advertisement

BRINKMANN-Cutter pumps SFC1520...3000
Limit of Application (Table 1)
SFC
Type
Mediums
Coolants,
cooling- and cutting-oils on
request.
Flashing point of the
≥ 150 °C
medium to be
pumped
Chip material
Aluminium, steel, coloured
steels
max. chip to coolant ratio by
weight: 1.5%
Chip geometry
Chip bundles to max. Ø 100
mm
Kinetic viscosity of
...45 mm
the medium
Temperature of me-
0 ... 80 °C
dium
Dry running
Dry running causes in-
creased wear and should be
avoided.
During the test of the direc-
tion of rotation (< 30 s) per-
missible.
Switching-on fre-
The pump SFC should be
quency per hour
operated in continual opera-
tion mode, not pulsed
mode.
Ambient tempera-
40 °C
ture
Set-up altitude
1000 m
ATTENTION
The pumps are to be operated within their design
limits.
Applications outside of these limits are not ap-
proved. The manufacturer is not responsible for any
damages resulting from use of the pumps in such
applications.
Technical data
2.3
Max. del.
pressure
bar / spec.
Type
weight 1
SFC1520 / 370
2.8
/ 500
/ 620
SFC1820 / 370
3.6
/ 500
/ 620
SFC2320 / 400
4.4
/ 530
/ 650
SFC3000 / 690
4.6
/ 940
1) Dimensions in accordance with drawing 1.
The motor is surface-cooled and compliant with
DIN IEC 34 and EN 60034 (protection degree IP 55).
BE3185
2
/s
Max. del.
Height
volume
l/min
H mm
1200
612
1200
620
1200
974
2500
1067
11/2019
Edition
WARNING
Risk of fire and explosion!
Pump may not be used in potentially explosive
environments.
1)
Depth of
Weight
1)
immersion
h mm
kg
372
502
622
372
502
622
400
530
650
693
943
Power
50 / 60 Hz
kW
144
7.5
8.6
149
153
173
11.0 12.6
176
180
223
18.5 21.3
227
233
273
33.5
287
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents