Installation Guide
Flap Barrier Turnstile-FBL6000 Pro series
Applicable Model(s): FBL1000 Pro series, FBL1200 Pro series, FBL2000 Pro series,
FBL2200 Pro series, FBL4000 Pro series, FBL4200 Pro series, FBL5000 Pro series,
FBL5200 Pro series, FBL6000 Pro series, FBL6200 Pro series
Version: 1.1
Date: December 2019

Advertisement

loading

Summary of Contents for ZKTeco FBL6000 Pro Series

  • Page 1 Flap Barrier Turnstile-FBL6000 Pro series Applicable Model(s): FBL1000 Pro series, FBL1200 Pro series, FBL2000 Pro series, FBL2200 Pro series, FBL4000 Pro series, FBL4200 Pro series, FBL5000 Pro series, FBL5200 Pro series, FBL6000 Pro series, FBL6200 Pro series Version: 1.1 Date: December 2019...
  • Page 2: Material Preparation

    It is recommended that the wiring is to be done by a professional. And the device must be connected to the ground. Below is the reference to FBL6000 Pro cabling. Figure 1-1 FBL6000 Pro series installation guide 1...
  • Page 3 3. Start the air switch inside the wing gate to check whether the wing gate functions properly and check whether the LED indicators function properly. If they all function properly, start the civil installation. If an exception occurs, contact your sales agent. Figure 2-1 Air Switch 2 FBL6000 Pro series installation guide...
  • Page 4 50 mm. Turn the wings to the OFF state. b) Test whether the infrared rays transmitted by infrared sensors on both sides align with each other. FBL6000 Pro series installation guide 3...
  • Page 5 Use a level to check whether the installation ground foundation is level. If not, use a pad for adjustment. Note: Eight expansion screws must be completely inserted, as shown in Figure 3-3. 4 FBL6000 Pro series installation guide...
  • Page 6 Figure 3-3 5. Card Swiping Warning Lines It is recommended that a warning line is set to prompt users to swipe cards outside the warning lines, as shown in Figure 3-4. Figure 3-4 FBL6000 Pro series installation guide 5...
  • Page 7: Menu Operation

    After the gate is opened, it will be automatically closed if no one passes through within a certain duration. The default value is 10 seconds. The value ranges from 5 to 60. 6. Reset the counter Out counter Into the counter All (default) 6 FBL6000 Pro series installation guide...
  • Page 8 Out of the anti-pinch area, close the gate. (default) Out of the channel, close the gate. 16. Memory opening Whether to open: No (default) 17. System working mode Mode: Working mode (default) Test mode Restore to factory 18. Version number Version: V7.0.3 FBL6000 Pro series installation guide 7...
  • Page 9: Wiring Diagram

    5 Wiring Diagram Below is the wiring diagram: Figure 5-1 8 FBL6000 Pro series installation guide...